Télécharger Imprimer la page

BFT EE Link RTD-CA Instructions D'utilisation page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
ENGLISH
Thank you for buying this product, our company is sure that you will be
more than satisfied with the product's performance. The product is
supplied with a "Warnings" leaflet and an "Instruction booklet".
These should both be read carefully as they provide important
information about safety, installation, operation and maintenance.
This product complies with the recognised technical standards and
safety regulations. We declare that this product is in conformity with
the following European Directives: 89/336/EEC and 73/23/EEC (and
subsequent amendments).
GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with
this product should be read carefully as they provide important
information about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc)
according to the provisions set out by current standards. Keep
nylon or polystyrene bags out of children's reach.
Keep the instructions together with the technical brochure for
future reference.
This product was exclusively designed and manufactured for the
use specified in the present documentation. Any other use not
specified in this documentation could damage the product and be
dangerous.
The Company declines all responsibility for any consequences
resulting from improper use of the product, or use which is
different from that expected and specified in the present
documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives:It complies with the 89/336/EEC,
1999/5/CEE, European Directive and subsequent amendments.
As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in
order to achieve a good safety level.
The Company declines all responsibility for any consequences
resulting from failure to observe Good Technical Practice when
constructing closing structures (door, gates etc.), as well as from
any deformation which might occur during use.
The installation must comply with the provisions set out by the
following European Directives:It complies with the 89/336/EEC,
1999/5/CEE, European Directive and subsequent amendments.
Disconnect the electrical power supply before carrying out any work
on the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power
supply, having a contact opening distance equal to or greater than
3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts
for closure (doors, gates etc.) and all system components provided
with an earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing.
Position at least one luminous signal indication device (blinker)
where it can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the
automation safety and correct operation when other manufacturers'
components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly
authorised by the company.
Instruct the product user about the control systems provided and
the manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation
operation area.
Keep radio control or other control devices out of children's reach,
in order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
12 - RTD-CA - Ver. 02
INSTALLATION MANUAL
Anything which is not expressly provided for in the present
instructions, is not allowed.
Installation must be carried out using the safety devices and
controls prescribed by the EN 12978 Standard.
1) GENERAL OUTLINE
Programmable self-learning radio receiver system, having the following
main features:
Receiver with 512 or 2048 codes
Up to 4 outputs (1 standard + 3 modular) with automatic recognition
of the modules entered
Outputs which can be configured as monostable, bistable, timed,
anti-aggression and access control
Programming by means of incorporated display
Access control functions by means of integrated WRTD board
Capable of recognising and memorising transmitters, proximity
cards, and transmitters enabled for access control
Compatible with EElink protocol for fast installation and
maintenance
Protection of receiver by means of password.
The integration of the receiver system, having transmitter cloning and
access control functions, provides a wide range of installations.
It allows the management of up to 4 passageways by means of radio
transmitters (MITTO/TRC) as well as transponders (Compass-Isocard/
Compass-Ring/MITTO T).
The radio transmitters (MITTO/TRC) can be managed by the RTD-CA
system, both as traditional radio transmitters and as proximity cards.
Using the COMPASS-232 optional interface, the system can be
monitored by the SECURBASE access control software (optional)
which provides full access control.
Passageway control is managed by an output with N.O. contact; when
needed, the number of outputs can be increased by means of
appropriate MOP optional modules to obtain a maximum of 4 output
channels, which can be configured independently.
2) TECHNICAL SPECIFICATIONS
2.1) RTD-CA Receiver
Power supply: ....................................................... 230V
Frequency: ....................................................................... 433.92MHz
Working temperature: .................................................... -20 to +55°C
Coded by means of: ....................................... Rolling-code algorithm
No. combinations: ................................................................ 4 milliard
Antenna impedance: .................................................. 50Ohm (RG58)
Dimensions: .......................................................................... see fig. 1
Relay contact: .................................................................. 0,5A - 12V=
Degree of protection: ................................................................ IP 20*
(*) The degree of protection of the container becomes IP55 with the
use of an accessory supplied on request. Only use fittings suitable for
the container dimensions and cable diameter.
2.2) WRTD board
Access to proximity card / transmitters enabled
The system parameters and code map are stored in a non-volatile
memory, which can keep the data entered for years, even with the
power supply disconnected.
The memory can manage up to 819 cards (RTD-CA 512) or 2500
cards (RTD-CA 2048).
The door-opening time can be freely set from 0 to 25.5 seconds.
The door-open control time can be freely set from 0 to 255
seconds.
2.3) MITTO transmitter
Keys: .......................................................................................... yellow
Power supply: 2 .......................... 3V lithium batteries (CR2016 type)
Range: ..................................................................... 50 – 100 metres
Transmitter versions:
MITTO2 – double-channel, MITTO4 – four-channel.
2.4) TRC transmitter
Keys: ............................................................................................... red
Power supply: ...................................................... 12V alkaline battery
Range: ..................................................................... 50 – 100 metres
Transmitter versions:
TRC1– single-channel, TRC2– double-channel, TRC4 – four-channel
±10%50Hz

Publicité

loading

Ce manuel est également adapté pour:

Ee link trc 1-2-4Ee link mitto 2-4