Operating the generator
8.4

Starting the generator

The generator can only be started if it is in standby and the control panel is switched
on.
I
NOTE
If the generator is still warm, press the start button briefly to start it; press
longer for a cold generator.
➤ Start up the generator with the green button "START/STOP (fig. 3 3, page 4).
8.5

Stopping the generator

➤ Stop the generator with the on/off switch (fig. 3 2, page 4).
If the generator does not stop: switch it off with the main switch (fig. 2 1,
page 3).
8.6

Display messages

Display message
Description
LOW BATTERY
The battery voltage has fallen
below the minimum value for
starting up (9V).
Check OIL Level
OIL CHANGE
The number of prescribed oper-
ating hours has been reached for
changing the engine oil.
NO FUEL
The diesel fuel in the tank is in
reserve.
16
Generator behaviour
The generator does not start.
The generator continues to run.
The generator continues to run.
The generator continues to run.
TEC40D EV
Measures
Charge the battery.
Fill up with oil (see chapter
"Checking the oil level" on
page 18).
Change the oil (see chapter
"Changing the oil" on page 22).
In order to reset the alarm start
up the generator by pressing
and holding down the
START/STOP button.
Refuel.