Troubleshooting - Dometic TEC40D EV Notice D'utilisation

Masquer les pouces Voir aussi pour TEC40D EV:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
TEC40D EV
11

Troubleshooting

Fault
Cause
The control panel
Starter battery is flat.
does not come on
Power cable is disconnected or the plug
when the on/off
is removed.
switch is pressed.
Fuse (if present) is triggered.
The starter does
Starter battery is flat.
not work when the
The main switch is at "0".
start button is
pressed.
Circuit board is damaged.
Starter is not receiving any power.
The starter turns
Fuel injector is dirty.
but the generator
Engine is defective.
does not start.
The generator
Too much oil in the engine.
tends to go off.
Load is too high.
Air intake is blocked.
Inverter is damaged.
Fault in the injection pump power supply.
Fuel injector is dirty.
The generator is
Inverter is damaged.
running but does
The electrical connections are not con-
not supply any volt-
nected properly.
age.
The generated
Load is too high.
voltage is unstable.
Air intake is blocked.
Inverter is damaged.
Fault in the injection pump power supply.
Fuel injector is dirty.
The battery
Battery charger fuse is damaged.
charger is not sup-
plying any voltage.
EN
Troubleshooting
Remedy
➤ Charge the starter battery.
➤ Contact an authorised workshop.
➤ Charge the starter battery.
➤ Set the main switch to "I" or "1".
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.
➤ Drain the oil (see chapter "Chang-
ing the oil" on page 22).
➤ Reduce the consumers.
➤ Check the air filter (see chapter
"Servicing the air filter" on
page 23).
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.
➤ Check the electric connections.
➤ Reduce the consumers.
➤ Check the air filter (see chapter
"Servicing the air filter" on
page 23).
➤ Contact an authorised workshop.
➤ Replace fuse.
25

Publicité

Table des Matières
loading

Table des Matières