DESCRIPTION AND OPERATION

The product you have purchased is a medium
pressure, industrial axial fan for air extraction into a
ventilation duct or directly to the outside. It is
designed for installation in ventilation ducts or for

WARNING - CAUTION

Warning:
• Do not use this appliance for functions other than
those described in this booklet.
• After removing the appliance from its packaging,
ensure that it is complete and undamaged. If in
doubt contact a professionally qualified electrician or
Vortice*. Do not leave packaging within the reach of
children or infirm persons.
• If you decide to stop using the appliance, switch it
Caution:
• Do not make modifications of any kind to this
appliance.
• Do not sit on the appliance or leave objects standing
on it.
• Regularly inspect the appliance for visible defects.
If any faults are found, do not operate the appliance;
contact Vortice* immediately.
• If the appliance does not function correctly or
develops a fault, contact Vortice* immediately.
Ensure that only genuine original Vortice spares are
used for any repairs.
• Should the appliance be dropped or suffer a heavy
blow, have it checked immediately by Vortice*.
• This appliance must only be installed
and serviced, externally or internally,
by professionally qualified personnel.
• Switch off the appliance at the installation's main
switch: a) if the appliance does not function
correctly; b) before cleaning the inside or outside of
the appliance, c) if the appliance is not to be used
for any length of time.
• Ensure that the electrical system to which the
appliance is connected complies with applicable
standards.
• Specifications for the power supply must correspond
to those on the appliance's data plate.
• The circuit in which the appliance is installed
must have an overload protection device
calibrated to suit the nominal current shown on
the appliance's data plate.
• This appliance must be connected to an efficient
earthing system in compliance with applicable safety
standards. If in doubt, ask a qualified electrician to
check your system.
• The electrical power supply/socket to which the
appliance is to be connected must be able to provide
*or an authorized Vortice dealer if you are outside the UK-Ireland territory
10
25/05/2007
11.55
this symbol indicates precautions that must be taken to avoid injury
this symbol indicates precautions that must be taken to avoid damaging the appliance.
Pagina 10
extraction through filters in applications where load
loss has be overcome. It must not be used to extract
dusty air or acidic or corrosive fumes (fig. 1).
off and disconnect it from the power supply.
• Do not use this appliance in potentially explosive or
flammable atmospheres or to extract acidic or
corrosive fumes (fig. 1).
• If the appliance is installed at a height below 2.5
metres from the floor, protection must be provided
for all moving parts, and the protection grille (fig. 2)
must be fitted.
the maximum electrical power required by the
appliance. If it cannot do so, arrange for a qualified
electrician to make the necessary modifications.
• When installing the appliance, fit a multi-pole
thermomagnetic cutout, with a contact gap of at
least 3 mm.
• If the appliance is installed outdoors, ensure that
adequate weather protection is provided.
• Operating temperature from -25°C to +70°C.
• The temperature of the extracted air must not
exceed 70°C (182°F).
• To ensure correct functioning of this appliance, you
must ensure that there is a sufficient air supply to
the room. If any unsealed fuel burning appliances
(e.g. boilers, gas stoves, etc.) are installed in the
same room, make sure that the air supply is
sufficient for this appliance and to ensure correct
combustion in the other appliance too.
• This appliance must not be used to switch on and
off boilers, heaters etc., nor must it discharge air into
the fume flues of such appliances.
• Do not cover the appliance's intake and outlet.
• Only fit the specified accessories over the intake
and outlet.
• Make sure that the room is adequately ventilated to
ensure proper air circulation.
• Do not allow dust to build up on the motor. This can
prevent correct cooling. Regular maintenance is
essential for correct functioning and to achieve the
declared levels of performance. Follow the
instructions in the figures on page 44 to perform the
necessary mechanical maintenance.
N.B.
Do not submerge the electric motor in water or
any other liquid.
ENGLISH