BFT X 130 Instructions D'utilisation Et D'installation page 9

Motorisations pour rideaux équilibrés
Masquer les pouces Voir aussi pour X 130:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both
be read carefully as they provide important information about safety,
installation, operation and maintenance. This product complies with the
recognised technical standards and safety regulations. We declare that this
product is in conformity with the following European Directives: 89/336/EEC
and 73/23/EEC, (and subsequent amendments).
1) GENERAL OUTLINE
Compact sturdy electromechanical operator for balanced roll-up doors,
provided with electrical limit switches which can be adjusted on opening
and on closing.
Available in two versions, reversible (X130) and irreversible (X130EF), the
latter provided with electric brake.
For irreversible versions, the emergency manoeuvre is carried out by means
of a knob attached to a wire.
The operator supplied is suitable for 60mm shafts and 220mm drive pul-
leys.
If necessary, 42mm and 48mm reduction half bearings, as well as 200mm
drive pulleys are available.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
The installation must comply with the provisions set out by the following
European Directives:89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing, according to and in compliance with the applicable directives
and technical standards.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation opera-
tion area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
INSTALLATION MANUAL
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Any safety device that should be required must be in compliance with
the EN 12978 Standard.
Check that the impact force value measured at the points established
by the EN 12445 standard is lower than that specified in the EN 12453
standard.
Fit any fixed control device within sight of the door, but away from any
moving parts, higher than 1.5 m.
3) TECHNICAL SPECIFICATIONS
Pulley diameter:........................................... X130:220mm - X130P:200mm
Power supply: ............................................................ 230V~±10% 50Hz (*)
Maximum weight:....... X130: 2000N (200 kg) .........X130P: 2200N (220 kg)
Absorbed power: .....................................................................X130...400W
..............................................................................................X130 P...423W
............................................................................................X130 EF...407W
........................................................................................... X130PEF..425W
Operation time: ................................................................................... 4' min
End-of-stroke revolutions: ......................................................................... 9
Output shaft revolutions: .................................................................12 min
Thermal protection: ......................................................................... present
Motor: ............................................................................. 2800 min
Capacitor for X130:..........................11µF 450V (230V): 40µF 250V (110V)
Capacitor for X130 EF: .................12,5µF 450V (230V): 50µF 250V (110V)
Insulation class: ......................................................................................... F
Circuit-breaking activation temperature:.................... 160°C (self-resetting)
Reduction gear lubrication:............................................. Permanent grease
Max. torque X130-X130 P-X130 EF-X130 PEF:..............................130 Nm
Impact reaction (safety edge): ...........................................stop and reverse
Limit devices:....................Electromechanical, incorporated and adjustable
Maximum no. manoeuvres in 24h:........................................................... 10
Working temperature: ........................................................... -10°C ÷ +50°C
Degree of protection: ............................................................................ IP20
Operator weight: ........................................................................60N (~6 kg)
Noise level: ................................................................................... <70dB(A)
Torque for reversibility (brake not fitted or released).............................4Nm
Dimensions:.................................................................................. See fig. 1
(*) Special power supply voltages available on request.
4) ACCESSORIES
-
PTP Drive pulley with 200mm diameter
-
PTG Drive pulley with 220mm diameter
-
CS 42 Pair of reduction half bearings for shafts with 42mm diameter
-
CS 48 Pair of reduction half bearings for shafts with 48mm diameter
-
EF Electric brake kit to be installed on X130 and X130P operators
5) MAIN OPERATOR COMPONENTS (Fig. 1)
Electromechanical operator comprising:
M Single-phase 2 pole motor protected by a thermal circuit breaker
C Roll-up door opener body
F Limit device adjustment box
P Drive pulley
E Electric brake with release mechanism (only on "EF" mod.)
6) PRELIMINARY CHECKS
Before fitting the motor, remove any redundant ropes or chains, and disable
any unnecessary appliance.
Check that the roll-up door characteristics are compatible with the maximum
torque specified and the operating time.
Check the weight of the roll-up door, check the diameter of the spring-holder
boxes and the diameter of the spring-holder shaft.
Choose the model with or without closing lock, depending on which is more
suitable for the type of installation.
If necessary, purchase the reductions for 42 or 48mm shafts (CS42 or CS48),
and also a pulley having the correct diameter.
NOTE: All the models supplied without an electric brake can be fitted with
one at a later time if required. (EF KIT).
In the case where greater capacity is required with respect to that supplied by a
single motor, fit a pair of X130 operators on the same spring-holder shaft.
Before carrying out the installation, carefully check that:
-
the roll-up door structure is sturdy and rigid;
-
the roll-up door slides evenly along its entire stroke, without any friction.
-
If the manoeuvre is difficult, grease the sliding tracks.
-
Repair or replace the worn or faulty components.
X130EF: 1800N (180 kg) ....X130PEF: 2000N (200 kg)
ENGLISH
-1
2 poles
-1
9
X130 - Ver. 01 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

X130pX130 efX130p ef

Table des Matières