Panasonic EYFPA1J Instructions D'utilisation page 13

Masquer les pouces Voir aussi pour EYFPA1J:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting the snug point detec­
tion level
(1)
A
B
1. Press the A button.
C
• The snug point detection level setting
value will be displayed.
EYFA31
Display
Battery indication lamp
. Press the
and
snug point detection level for the work
you're performing.
. Press the OK button to accept the number
of torque stages and the snug point detec-
tion level.
• The tool's panel will flash and then light
up continuously.
Snug point detection level guide­
lines
Snug point
Display
detection level
Low
(Use for work
characterized by
L1
low loads before
the snug point is
reached.)
High
(Use for work
characterized
L
by high loads
before the
snug point is
reached.)
CAUTION:
• Set the snug point detection level from
"L1." Setting the snug point detection level
from "L2" may result in cracking or defor-
mation of the target material.
()
()
D
buttons to set the best
Applications
(reference)
• Tightening bolts in
materials that are
easily cracked or
deformed, etc.
• Tightening bolts
in materials with
misaligned holes,
etc.
• Tightening self-
tapping screws,
etc.
- 1 -
• If the tool stops before the snug point at
snug point detection level "L1," set the
snug point detection level to "L2."
• Changing the snug point detection level
from "L1" to "L2" may increase the torque.
Set the number of torque stages again
after making this change.
• The setting will not be changed until
you press the OK button.
• After changing the setting, be sure to check
the new setting value. (See page 16.)
IMPORTANT INFORMATION:
• You can set the snug point detection
level and retightening prevention time at
the same time by changing the retight-
ening prevention time (See page 1)
before pressing the OK button and then
pressing the OK button.
• Pressing the A button toggles the dis-
play between the snug point detection
level setting value and the number of
torque stages setting value.
• The tool ships with the snug point
detection level set to "L1."
• When the number of torque stages has
been set as shown below, the snug
point detection level cannot be switched
from "L1" to "L2."
Number of torque stages
Model
EYFPA
Cross thread reduction func­
tion
• The tool runs in reverse approximately
60° before running forward to assist in
the alignment of the threads to help reduce
cross threads.
1. Set the tool to setting configuration mode.
(See page 11.)
. Press the D button once.
• The cross thread reduction function set-
ting value will be displayed.
. Press the
and
setting to ON or OFF.
Display
R0
R1
4. Press the OK button to accept the new
setting.
setting
1 to 0
buttons to change the
Function
OFF
ON
EN
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Eyfpa1jr

Table des Matières