Caution Messages - Sony VPL-X2000U Manuel D'installation

Masquer les pouces Voir aussi pour VPL-X2000U:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Symptom
The Remote Commander does not
work.
The wireless Remote Commander
does not function.
INPUT A cannot be selected.
The COVER FAIL indicator lights.
The LAMP FAIL indicator lights.
The FAN indicator lights.
The HIGH TEMP indicator lights.
When you press the ZOOM, SHIFT
or FOCUS key, "LENS CONTROL
is locked! Do you wish to unlock ?"
appears.

Caution messages

Message
High Temperature!
Power off in 1 min.
Frequency is out of range!
Please check INPUT-A in SIGNAL
SELECT.
Please check INPUT-B in SIGNAL
SELECT.
Please check INPUT-C in SIGNAL
SELECT.
Cause
The batteries are exhausted.
The remote control cable is connected
to the Remote Commander although
you are using it as a wireless Remote
Commander.
The fluorescent lamp influences on the
Remote Commander detector.
You have selected a wrong index
number.
You have set the index number to "00".
The SIRCS RECEIVER setting is not
correct.
The switcher is not connected, but is
recognized to be connected.
The lamp cover or air filter cover is
detached.
The lamp with the same number of the
indicator has reached the end of its
life.
The fan is broken.
The internal temperature is unusually
high.
The lens control function is locked.
Use the list below to check the meaning of the messages displayed on the
screen.
Meaning
Internal temperature becomes too high.
The frequency of the input signal is out
of the acceptable range.
You have input the RGB signal from
the computer when INPUT-A in the
SIGNAL SELECT menu is set to
COMPONENT or YP
P
.
B
R
You have input the RGB signal from
the computer when INPUT-B in the
SIGNAL SELECT menu is set to
COMPONENT or YP
P
.
B
R
You have input the RGB signal from
the computer when INPUT-C in the
SIGNAL SELECT menu is set to
COMPONENT or YP
P
.
B
R
Remedy
Replace the batteries with new ones (see
page 19 (GB)) .
Disconnect the remote control cable.
Change the setting of SIRCS RECEIVER in
the SET SETTING menu (see page 56 (GB)) .
Select the correct index number (see pages 45
(GB) and 56 (GB)) .
Select the correct index number (see page 45
(GB)) .
Change the setting of SIRCS RECEIVER in
the SET SETTING menu (see page 56 (GB)) .
If the PJ COM connector is connected to
something other than the terminator, remove it
then press the SYS SET key, or the LIGHT
and RESET keys on the control panel.
Attach the lamp cover or air filter cover
securely (see pages 63 (GB) and 65 (GB)) .
Replace the lamp (see page 64 (GB)) .
Consult with qualified Sony personnel.
Check to see if nothing is blocking the
ventilation holes.
Consult with qualified Sony service personnel.
Remedy
Turn off the power. (If not, the power is
automatically turned off about one minute
later.) Check to see if nothing is blocking the
ventilation holes.
Input a signal that is within the range of the
frequency.
Set INPUT-A correctly.
Set INPUT-B correctly.
Set INPUT-C correctly.
67
(GB)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vpl-x2000eVpl-x2000m

Table des Matières