Télécharger Imprimer la page

Technical Specifications; Cds3 12V/80A And 24V/60A - ENAG CDS3 12V/80A Manuel D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
5.

TECHNICAL SPECIFICATIONS

5.1.
CDS3 12V/80A
Models
Input
Voltage
Output power from 85 to 170Vac
Frequency
Current intensity 230/115Vac
Power factor
Efficiency
Input fuses
Output
Number of outputs
Total rated current (+/-7%) / Rated power
Load curve
Type of batteries
Regulated and filtered output voltage
Regulation tolerance before distributors and
fuses
Peak-to-peak ripple and noise
Automotive output fuses mounted in
parallel in the BAT pole -
Environment
Operating temperature
Cooling
Relative humidity
Storage temperature
Casing
Material
Paintwork
Dimensions excluding cable gland (length,
height, depth) / Weight
Fixing centre distances
Fixing screw (wall)
Protection factor
Board protection
Standards
CE/EMC marking
CE/safety marking
Electrical protections
24V/60A
AND
3 separated outputs BAT D, BAT 1 and BAT 2 (integrated distributor)
1 additional output +SP (before integrated distributor) for specific use, do not
connect it directly to a battery
Each output can be used on its own and supply the entire current.
Type of charge selected using internal switch IU or IUoU (Boost, Absorption,
See selection wheel setting table. The chargers can operate on DC supply.
4 x 25A/32V (F3, F4, F5, F6)
Rated conditions: from - 10°C to + 55 °C; over, de-rating : reduction of the
Casing comprises :
Steel frame and steel front cover
Polycarbonate clasp
NF EN61000-6-1, NF EN61000-6-2, NF EN61000-6-3, NF 61000-6-4
- Against leaking input surges by rupture of VDR (voltage dependent resistor)
(not covered by warranty)
- Against output polarity reversals by rupture of fuses
- Against output short-circuits and surges
- Against abnormal overheating by cutting off the charger (internal temperature
probe 90°C), Automatic re-start
- Against output surges (17V
CDS3/12-80
from 85 to 265VAC single phase
100%
From 47 to 65Hz
6A/13A
0,9 in rated conditions
> 80% in rated conditions
2 x 25A RIT/250V – 6,3x 32 (F1/F2)
80A/1140W
Floating – factory setting).
See selection wheel setting table
< 2% (in rated conditions)
< 2% (in rated conditions)
output power < than 2,5 %/°C up to 65°C
Controlled draft fan at 15% of the rated current of the charger
Up to 70% (95% with no condensation)
Grey, black matt epoxy coating
350 x 260 x 123mm / 7,7Kg
4 M5 round screws
IP22 (with cable glands)
Protected with water-repellent varnish (marine environment)
NF EN60950, NF EN60335-2-29
±5% for12V)
CDS3-3M-DEE
CDS3/24-60
9A/14A
60A/1710W
3 x 25A/32V (F3, F4, F5)
-20°C to +70°C
329 x 154 mm
±5% for 24V)
(34V
85%
40

Publicité

loading

Ce manuel est également adapté pour:

Cds3 24v/60aCds3 48v/30aCds3 24v/75a