5

TECHNICAL SPECIFICATIONS

CDS4 12V-25A, 24V-12A
Part Number
Model
recommended battery bank (Ah)
Input
Voltage
Frequency
Input current consumption
230/115VAC
Recommended power for a generator
Power factor
Efficiency
Input fuses
Output
Number of battery bank
Total rated current (+/-7%) /
Rated power
Charging curve
Battery type
Boost voltage
Floating voltage
Regulation tolerance before output
Mosfet splitter and fuse
Peak to peak ripple and noise
Automotive output fuse mounted in
series in minus pole -BAT
Environment
Cooling
Sound level
Operating temperature at 230VAC
Storage temperature
Relative humidity
Casing
Material
Dimensions (length, height, depth) /
Weight
Fixing center distance
Fixing screw (wall)
Protection factor
PCB protection
Standards
CE declaration of conformity
CE / EMC
CE / Security - Others
Ignition protected
Protections
Options
Temperature probe
Communication
CDS4-1M-2M-G - 03 EN.docx
CDS4 12-25
12V/25A
200-300Ah
1.7/3.4A
435W
T6,3A/250V - SCHURTER MST 250 Ref. 0034.6623 (F101)
3 (including one for the engine battery) : +BAT E, +BAT 1 et +BAT 2 (integrated Mosfet splitter )
Each bank can be used individually and deliver the rated current
25A/356W
IU or IUoU through internal dip switches (Boost, Absorption, Floating and Refresh – factory setting)
Lead sealed as factory setting - Other choices through internal setting :
14.4VDC for Lead sealed battery (factory setting)
13.8VDC for Lead sealed battery (factory setting)
1 x 30A/32V (F500)
From -20°C to +60°C, derating from 60°C. Above 65°C, automatic charger switch off, automatic restart when temperature
Casing comprises 3 parts :
· Aluminium sink frame
· Thermoplastic body
· Aluminium clasp
NO
- Against leaking input surges by VDR rupture (voltage dependent resistor) - Not covered by warranty
- Against output polarity reversal by fuse rupture (removable automotive type)
- Against short-cuircuit and surge
- Against abnormal overheating by cutting off the charger (internal temperature probe - automatic restart)
Output voltage compensation : -18mV/°C
from 90 to 265VAC single-phase automatic
from 47 to 65Hz automatic
1
90% typical
1 -BAT
gel, AGM, Calcium Lead, Stabilized power supply, etc.
28.8VDC for Lead sealed battery (factory setting)
27.6VDC for Lead sealed battery (factory setting)
< 2% (at rated conditions)
< 2% (at rated conditions)
Natural (fanless)
0
decreases
From -20°C to +70°C
up to 70% (95% without condensation)
236 x 180 x 96 mm / 2.1kg
219 x 155 mm
4 off M5 round head screws
IP22
Water-repellent varnish (marine environment)
Available on request
EN61204-3
EN60335-2-29. Pending UL and CSA.
CAN BUS interface
CDS4 24-12
24V/12A
100-200Ah
1.7/3.4A
420W
12A/342W
1 x 15A/32V (F500)
NO
Output voltage compensation : -36mV/°C
34