CDS4 12V-40A, 12V-60A, 24V-20A, 24V-30A
Part Number
Model
recommended battery bank (Ah)
Input
Voltage
Frequency
Input current consumption
230/115VAC
Recommended power for a generator
Power factor
Efficiency
Input fuses
Output
Number of battery bank
Total rated current (+/-7%) /
Rated power
Charging curve
Battery type
Boost voltage
Floating voltage
Regulation tolerance before output
Mosfet splitter and fuse
Peak to peak ripple and noise
Automotive output fuse mounted in
series in minus pole -BAT
Environment
Cooling
Sound level
Operating temperature at 230VAC
Storage temperature
Relative humidity
Casing
Material
Dimensions (length, height, depth) /
Weight
Fixing center distance
Fixing screw (wall)
Protection factor
PCB protection
Standards
CE declaration of conformity
CE / EMC
CE / Security - Others
Ignition protected
Protections
Options
Temperature probe
Communication
CDS4-1M-2M-G - 03 EN.docx
CDS4 12-40
12V/40A
300-500Ah
2.7/5.6A
700W
T15A/250V - 6,3x32 (F101)
3 (including one for the engine battery) : +BAT E, +BAT 1 et +BAT 2 (integrated Mosfet splitter )
Each bank can be used individually and deliver the rated current
40A/570W
IU or IUoU through internal dip switches (Boost, Absorption, Floating and Refresh – factory setting)
Lead sealed as factory setting - Other choices through internal setting :
gel, AGM, Calcium Lead, Stabilized power supply, etc.
14.4VDC ffor Lead sealed battery (factory setting)
13.8VDC for Lead sealed battery (factory setting)
2 x 25A/32V (F500, F501)
IGNITION PROTECTED FUSE
BUSSMAN BK-ATC-25M ONLY
Natural (fanless) - Electric fan controlled in temperature and current for 12V/60A and 24V/30A models
0
From -20°C to +60°C, derating from 60°C. Above 65°C, automatic charger switch off, automatic restart when
Casing comprises 3 parts :
· Aluminium sink frame
· Thermoplastic body
· Aluminium clasp
289 x 195 x 106 mm / 3.5kg
YES
- Against leaking input surges by VDR rupture (voltage dependent resistor) - Not covered by warranty
- Against output polarity reversal by fuse rupture (removable automotive type)
- Against short-cuircuit and surge
- Against abnormal overheating by cutting off the charger - automatic restart
Output voltage compensation : -18mV/°C
CDS4 12-60
CDS4 24-20
12V/60A
500-700Ah
from 90 to 265VAC single-phase automatic
from 47 to 65Hz automatic
4.4/8.7A
1050W
1
90% typical
1 -BAT
60A/855W
28.8VDC for Lead sealed battery (factory setting)
27.6VDC for Lead sealed battery (factory setting)
< 2% (at rated conditions)
< 2% (at rated conditions)
3 x 25A/32V
2 x 15A/32V
(F500, F501, F502)
(F500, F501)
< 50dBa at 1m
temperature decreases
From -20°C to +70°C
up to 70% (95% without condensation)
272 x 170 mm
4 off M5 round head screws
IP22
Water-repellent varnish (marine environment)
Available on request
EN61204-3
EN60335-2-29. Pending UL and CSA.
NO
Output voltage compensation : -36mV/°C
CAN BUS interface
CDS4 24-30
24V/20A
24V/30A
200-300h
300-500Ah
2.9/5.9A
4.5/8.8A
700W
1050W
T15A/250V - 6,3x32 (F101)
20A/570W
30A/855W
2 x 20A/32V
(F500, F501)
0
< 50dBa at 1m
289 x 195 x 106 mm / 3.5 kg
NO
NO
35