IKA HS 260 basic Mode D'emploi page 23

Masquer les pouces Voir aussi pour HS 260 basic:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

back on, both functions must be started again. The upper speed limit
can only be set or changed in operating mode A. You can recognice
operating mode A by the fact that no star is displayed in the menu bar
display of the time setting.
After the power has been interrupted, the device will no longer auto-
matically start up in operating mode A by itself any more.
After you have selected the operating mode and turned on the device,
the following process will be shown on the display.
a.) All display elements in the digital displays are activated for about 2
seconds.
b.) The device type (left display) and operating mode (right display) are
displayed for about 2 seconds.
2 6 0
K S
c.) After this, the set (ore stored) upper speed limit of the agitator
is shown in the left display with SAFE, the unit of measure rpm and
flashing SV for about 2 seconds. As long as the display is flashing
with SV , it is possible to change the upper speed limit by pressing
the turn button and turning at the same time.
2 3 0
S A F E
I
/
m i n
SV
d.) If the upper speed limit is fixed, the unit 1/min in the left display
changes to OK. The new time target value that is set or stored in the
right display (for example 3:58) is displayed with an indication of h
min and a flashing SV .
2 3 0
S A F E
O K
SV
e.) The new speed target value that has been set or stored in the left
display (for example 130) is then shown with the unit 1/min and
flashing SV .
I 3 0
I
/
SV
f.) By pressing the left or the right turn button, you can place the agi-
tator in operation with the stored value or the one that has just been
A
set. The actual speed and time values are then shown in large format
on the display. The actual value of the time setting must be understood
from this point onward as the time remaining for the agitation process.
If zhe remaining has reached zero, the agitator stops its motion.
I 3 0
I 3 0
I
/
PV
Operating mode B:
A
When the device is turned on, target values for speed and time setting
are adopted before the device is turned off (power OFF). The upper
speed limit that has been set is taken over from operating mode A
when this operating mode is selected and cannot be modified.
When you turn on the device with the power switch, a B is shown on
3 5 8 :
i
n
m i n
SV
3 5 8 :
i
m i n
n
m i n
SV
3 5 6 .
3 5 8 :
i
m i n
n
m i n
PV
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ks 260 basicHs 260 controlKs 260 control

Table des Matières