Honsel RivSmart eBZ ZERO S Manuel D'utilisation D'origine page 46

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MANUAL / AUTOMATIC RETURN
Pressing the trigger (I) activates the riveter. In
manual return mode, the riveter (P) is activated as
long as the trigger (I) is pressed. When the riveter
(P) reaches its end position, it stops until the trigger
is released.
In automatic return mode, the trigger (I) only has
to be pressed once. The stroke is then performed
automatically. The return stroke starts on detection
of the rivet break-off or when the end position is
reached. Both modes can be set in the setup menu
and in the app.
SERVICE
CLAMPING JAWS / RIVET STUD MATERI-
AL
The riveter (P) has a warning function for clamping
jaw service. For this it is important that the material
of the rivet studs (!!) (not of the sleeve) is select-
ed in the setup menu or the app. When the set
number of rivets is reached, a warning message for
clamping jaw service is displayed. The clamping
jaw mechanism should then be cleaned (see
"Servicing and changing the clamping jaws") and
the clamping jaws replaced, if necessary. As rivet
studs of the same material can differ, depending
on the manufacturer and rivet type, it is possible
in the app to set the service intervals individually
according to the material.
STUD COLLECTOR (E) / STUD COUNTER
The stud collector (E) is equipped with an elec-
tronic contact. This prevents the riveter being used
without stud collector (E).
Never operate the riveter (P) without the
stud collector (E) and never bypass the
safety switch. Risk of injury!
If you need to use the riveter (P) without stud
collector (E) for space reasons, you can fit the stud
securing cap (J) instead of the stud collector and
discharge the rivet studs from the riveter to the
front.
46 | English
Never operate the riveter with stud
securing cap (J) and retainer mouthpiece
(A) at the same time. The rivet studs
could then not be discharged to either the
front or the rear. This would cause serious damage
to the riveter!
If the stud collector (E) or stud securing cap (J) is
not fitted correctly, a warning message appears on
the display (S).
A warning message also appears when the stud
collector (E) is full. The limit is set to 100 rivet
studs; this value can be changed in the app. Every
time you remove the stud collector (E), it must be
emptied as removing the stud collector resets the
counter to zero.
Do not overfill the stud collector (E). This
would cause serious damage to the
riveter!
A larger stud collector (E) is available for longer
rivet studs.
RIVETER
The riveter (P) has a service counter that sig-
nals when the riveter needs to be serviced. This
warning appears every time you fit the battery (F)
and can only be reset by a service station as part
of a service routine. Contact your nearest service
station for further information.
LANGUAGE
Languages currently available in the riveter (P) and
the app are English, German, French and Spanish.
The language can be selected in the setup menu
and in the app.
LIGHT
Via the light function you can switch between
riveting point illumination (H) that is active only
during operation of the riveter (P) and the torch
function.
Riveting point illumination (H) goes out together
with the riveter after 30 seconds' inactivity.
With the torch function, the LED remains on for
3 minutes.

Publicité

Table des Matières
loading

Table des Matières