Dometic 10 Série Instructions De Montage page 18

Réfrigérateur à absorption
Masquer les pouces Voir aussi pour 10 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installing the refrigerator
5.3
Making air inlet and outlet vents
I
NOTE
• Deviations from the inlet and outlet variations shown here must be
approved by the manufacturer.
• At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been pro-
vided.
➤ Make an air inlet vent and an air outlet vent in the outer wall with the size of
– LS230: 315 mm x 373 mm
– LS330: 249 mm x 410 mm
When doing so, observe the information, see chapter "Preparing the installa-
tion" on page 15.
If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the
niche, install an inlet vent in the floor. Any leaking gas can thus flow downwards.
➤ Make an air inlet vent of at least Ø 40 mm in the floor (fig. 8 1, page 7) behind
the refrigerator near the gas burner.
➤ Shield the outside of the opening with a deflector to prevent sludge or dirt from
getting inside while driving (fig. 8 2, page 7).
If you have to use a roof vent instead of the air outlet vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions.
When doing so, observe the information in chapter "Preparing the installation"
on page 15.
5.4
Installing the ventilation grill
I
NOTE
Use exclusively original Dometic ventilation grills to ensure safe opera-
tion.
No. in
fig. 9, page 7
1
2
18
Description
Installation frame
Ventilation grill
RML10.4, RML10.4S, RML10.4T
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rml 10.4Rml 10.4sRml 10.4t

Table des Matières