10.1. EMPTYING THE WATER CIRCUIT
1.
Remove the suction and discharge hoses;
2.
Tilt the pump to drain the water from the pump casing throught the discharge flange;
3.
Clean the pump body with clear water;
4.
Allow water to drain completely.
10.2. EMPTYING THE FUEL CIRCUIT
■ Operation to be avoided in the vicinity of a heat source, open flame or other conditions that may
cause a fire.
■ Do not smoke.
1.
Place a container under the tank to collect fuel;
2.
Remove the fuel tank cap [Fig. 06];
3.
Unscrew the drain plug [(g) Fig. 26 and 27] and remove the joint [(f) Fig. 26 et 27] under fuel tank
and let the fuel flow into the container and empty the tank;
4.
Replace the joint and screw the drain plug;
5.
Replace the fuel tank cap.
■ If fuel is spilled, wipe it off and let dry before starting the engine.
WARNING