alpha innotec SWP Série Mode D'emploi page 47

Masquer les pouces Voir aussi pour SWP Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model
Air-to-water heat pump: (yes/no)
Brine-to-water heat pump: (yes/no)
Water-to-water heat pump: (yes/no)
Low-temperature heat pump: (yes/no)
Equipped with supplementary heater: (yes/no)
combination heater with: (yes/no)
application: (low/medium)
climate: (colder/average/warmer)
Item
Rated heat output
Declared coefficient of performance for part load at
indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Tj = +2°C
Tj = +7°C
Tj = +12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps: Tj =
+15°C (if TOL < -20°C)
Bivalent temperature
Cycling interval capacity for
heating
Degradation co-efficient (**)
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Capacity control
sound power level,
indoors/outdoors
Emissions of nitrogen oxides
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load
for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for
heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Sous réserve de modifications techniques | 83050900cFR – Traduction du mode d'emploi | ait-deutschland GmbH
Symbol
Value
Unit
Prated
kW
162
Pdh
161,8
kW
Pdh
kW
161,7
Pdh
161,7
kW
Pdh
161,6
kW
Pdh
kW
161,9
Pdh
kW
161,9
Pdh
161,9
kW
Tbiv
°C
-10
Pcych
kW
Cdh
-
1,0
POFF
0,010
kW
PTO
kW
0,010
PSB
0,010
kW
PCK
kW
0
fixed
LWA
81/-
dB
NOX
0
mg/
kWh
-
Qelec
kWh
-
ait deutschland GmbH Industriestr. 3 95359 Kasendorf Germany
SWP 1600
no
yes
no
no
no
no
medium
average
Item
Seasonal space heating energy
efficiency
Declared coefficient of performance for part load at
indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Tj = +2°C
Tj = +7°C
Tj = +12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps: Tj =
+15°C (if TOL < -20°C)
For air-to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
Heating water operating limit
temperature
Supplementary heater
Rated heat output
Type of energy input
For air-to-water heat pumps:
Rated air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Water heating energy efficiency
Daily fuel consumption
Unit
Symbol
Value
ηS
%
116,0
COPd
3,05
-
COPd
-
3,47
COPd
3,79
-
COPd
4,18
-
COPd
-
2,95
COPd
-
2,95
COPd
2,95
-
TOL
°C
-10
COPcyc
-
WTOL
°C
55
Psup
0,0
kW
electrical
-
m³/h
-
m³/h
29100
-
ηwh
%
-
Qfuel
kWh
0
47

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Swp 1100Swp 1250Swp 1600Swp 700hSwp 850hSwp 1000h

Table des Matières