Swp 1250 - alpha innotec SWP Série Mode D'emploi

Masquer les pouces Voir aussi pour SWP Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model
Air-to-water heat pump: (yes/no)
Brine-to-water heat pump: (yes/no)
Water-to-water heat pump: (yes/no)
Low-temperature heat pump: (yes/no)
Equipped with supplementary heater: (yes/no)
combination heater with: (yes/no)
application: (low/medium)
climate: (colder/average/warmer)
Item
Rated heat output
Declared coefficient of performance for part load at
indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Tj = +2°C
Tj = +7°C
Tj = +12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps: Tj =
+15°C (if TOL < -20°C)
Cycling interval capacity for
heating
Degradation co-efficient (**)
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
sound power level,
indoors/outdoors
Emissions of nitrogen oxides
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load
for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for
heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
44
Symbol
Value
Unit
Prated
kW
125
Pdh
kW
125,1
Pdh
125,1
kW
Pdh
kW
125,1
Pdh
125,1
kW
Pdh
kW
125,1
Pdh
125,1
kW
Pdh
125,1
kW
Tbiv
-10
°C
Pcych
kW
Cdh
1,0
POFF
0,010
kW
PTO
kW
0,010
PSB
0,010
kW
PCK
kW
0
fixed
LWA
79/-
dB
NOX
0
mg/
kWh
-
Qelec
-
kWh
ait deutschland GmbH Industriestr. 3 95359 Kasendorf Germany
Sous réserve de modifications techniques | 83050900cFR – Traduction du mode d'emploi | ait-deutschland GmbH

SWP 1250

no
yes
no
no
no
no
low
average
Item
Seasonal space heating energy
efficiency
Declared coefficient of performance for part load at
indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Tj = +2°C
Tj = +7°C
Tj = +12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps: Tj =
+15°C (if TOL < -20°C)
For air-to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
-
Heating water operating limit
temperature
Supplementary heater
Rated heat output
Type of energy input
For air-to-water heat pumps:
Rated air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Water heating energy efficiency
Daily fuel consumption
Symbol
Value
Unit
ηS
%
155,0
COPd
-
4,33
COPd
4,58
-
COPd
-
4,84
COPd
5,12
-
COPd
-
4,28
COPd
4,28
-
COPd
4,28
-
TOL
-10
°C
COPcyc
-
WTOL
°C
55
Psup
0,0
kW
electrical
m³/h
-
-
22300
m³/h
-
ηwh
-
%
Qfuel
0
kWh

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Swp 1100Swp 1250Swp 1600Swp 700hSwp 850hSwp 1000h

Table des Matières