Télécharger Imprimer la page

Device Information; Operating Limits - Dimplex HPL 9S-TUW Instructions D'installation Et D'utilisation

Masquer les pouces Voir aussi pour HPL 9S-TUW:

Publicité

Les langues disponibles

Les langues disponibles

HPL 9S-TU(R)W - HPL 18S-TU(R)W

12 Device information

1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Installation location
2.4
Thermal energy metering
2.5
Performance levels
3

Operating limits

3.1
Heating water flow / return
1
3.2
Air (heating)
4
4
Flow
/ sound
4.1
Heating water flow heat pump circuit / free compression
Nominal flow in accordance with EN 14511
4.2
Minimum heating water flow rate
Heat pump circuit
4.3
Sound power level according to EN 12102
Normal operation / reduced operation
4.4
Sound pressure level at a distance of 10 m (air outlet side)
Normal operation / reduced operation
4.5
Air flow
Normal operation / reduced operation
5
Dimensions, weight and filling quantities
5.1
Device dimensions without connections
mm
5.2
Device connections for heating
5.3
Weight of the transportable unit(s) incl. packaging
5.4
Refrigerant / total filling weight
5.5
Lubricant / total filling quantity
5.6
Volume of heating water in device
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
6.2
Control voltage / fusing by WPM
6.3
Degree of protection according to EN 60529
6.4
Starting current limiter
6.5
Rotary field monitoring
6.6
Starting current with soft starter
6.7
Nominal power consumption A2/W35/ max. power consumption
Nominal current A2 /W35 / cos 
6.8
6.9
Power consumption of compressor protection
(per compressor)
6.10 Power consumption of fan
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Frost protection, condensate tray /
Water in device protected against freezing
8.3
Maximum operating pressure (heat sink)
8.4
Energy efficiency class / energy efficiency (low temperature)
8.5
Energy efficiency class / energy efficiency (mean temperature)
4
9
Heat output COP
9.1
Heat output / COP
EN-10
Heat Pump / Hydro tower
1
°C
°C
at A7 / W35...30
m³/h / Pa
at A7 / W45...40
m³/h / Pa
at A7 / W55...47
m³/h / Pa
m³/h / Pa
6 7
dB(A)
8
6 7
dB(A)
6
m³/h
H x W x L
inches
kg
type/kg
type/litres
Litres
A
A / ---
W / ---
W
10
bar
Performance level
452168.66.05 · FD 9512
HPL 9S-TUW
Air
Universal with hydro
tower
Integrated (hydro tower)
Integrated (hydro tower)
Outdoors / Indoors
Integrated
1
up to 60 ± 2 / from 18
up to 60 ± 2 / from 18
-22 to +35
1,5 / 41000
1,4 / 46000
5
0,9
/ 67000
1,2
53 / 53
25 / 25
2700 / 2100
1650 x 910 x 750
G 1 1/4" external thread
G 1 1/4" external thread
225
R410A / 3.9
Polyolester (POE)/1.2
Polyolester (POE)/1.2
2.6
3~/N/PE 400 V (50 Hz) /
3~/N/PE 400 V (50 Hz) /
C10 A / A
1~/N/PE 230 V (50 Hz) /
1~/N/PE 230 V (50 Hz) /
4 AT
IP 24
Soft starter
Yes
21
4
1,7 / 3.3
kW
3,1 / 0,8
70 / thermostatically
controlled
up to 100
9
Reverse circulation
Yes
3.0
A++ / 177 %
A++ / 127 %
EN 14511
1
2
HPL 12S-TUW
HPL 18S-TUW
Air
Air
Universal with hydro
Universal with hydro
tower
tower
Integrated (hydro tower)
Outdoors / Indoors
Outdoors / Indoors
Integrated
Integrated
1
2
up to 60 ± 2 / from 18
-22 to +35
-22 to +5
1,9 / 18000
1,5 / 40900
1,8 / 24000
1,4 / 45900
5
5
1,2
/ 55000
1,4
/ 66900
1,4
1,4
54 / 53
54 / 53
26 / 25
26 / 25
4700 / 3600
5500 / 3200
1650 x 910 x 750
1650 x 910 x 750
G 1 1/4" external thread
265
295
R410A / 4.78
R410A / 5,9
Polyolester (POE)/1.2
3.8
3.8
3~/N/PE 400 V (50 Hz) /
C10 A / A
C13 A / A
1~/N/PE 230 V (50 Hz) /
4 AT
4 AT
IP 24
IP 24
Soft starter
Soft starter
Yes
Yes
19
21
2,38 / 4,0
3,24 / 6,8
4,3 / 0,8
5,9 / 0,8
70 / thermostatically
70 / thermostatically
controlled
controlled
up to 150
up to 200
9
9
Reverse circulation
Reverse circulation
Yes
Yes
3.0
3.0
A++ / 173 %
A++ / 168 %
A++ / 128 %
A++ / 133 %
EN 14511
EN 14511
1
2
1
www.dimplex.de
2
3
/ +35
2

Publicité

loading

Ce manuel est également adapté pour:

Hpl 12s-tuwHpl 18s-tuwHpl 9s-turwHpl 12s-turwHpl 18s-turw