EHMB
Installing the effective load
·
Place the centre of gravity of the effective
load if possible centrically to the drive shaft.
·
Fasten the effective load to the drive shaft
with at least 2 screws and 2 centring
sleeves or with the aid of adapter kits
(è Assembly instructions of the
adapter kit).
EHMB−...
Screw
Tightening
torque
Max. screw−in
depth E
Centring sleeve
Fig. 13

Electrical installation

·
Check whether additional proximity sensors are required. Two trip cams are on
hand for sensing the rotation.
To set the trip cams:
·
Disconnect the threaded pin in the trip
cam.
·
Move the cams onto the desired position.
·
Tighten the threaded pins (D è Fig. 16)
lightly at first. After final positioning with
tightening torque: 0.7 Nm.
·
Screw the proximity sensor (E) into the
sensor bracket (F).
If necessary, the sensor bracket can be
mounted off−set by 90° (EHMB−20/32)
or 180° (EHMB−25).
26
20
25
M6
M8
[Nm]
9.9
24
[mm] 9.6
14
[mm] dia. 9x4 dia. 12x4
Fig. 12
32
Fig. 14
Festo EHMB 0912NH English
(G)
(F)
(E)