2.
INSTALLATION
AND
PRELIMINARY
OPERATIONS
Once the machine is out of the packaging and
its integrity, and that of the accessories has
been checked, place it on a flat, horizontal
surface and if necessary, use the adjustable
feet to make sure it is correctly level:
up to a maximum of + 1 cm;
machine.
In the case in which the depth of the seating
surface is not sufficient, it is possible to move
the front feet by 4 cm. The operation must be
performed by a qualified technician.
It is advisable to install a softener ( ) and then
a mesh filter ( ) on the external part of the
plumbing system, during preliminaries and after
levelling the machine.
In this way impurities like sand, particles of
calcium, rust etc.. will not damage the delicate
graphite surfaces and durability will be guaran-
teed.
Following these operations, connect the plumb-
ing systems as illustrated in the following figure.
Recommended mains pressure for the
Avoid throttling in the connecting tubes.
Assess that the drain pipe (3) is able to
eliminate waste.
1
KEY
Fig. 5
Softener
Mesh filter
3 Drain Ø 50 mm
NOTE: For a correct functioning of the machine
the water works pressure must not
exceed 4 bars. Otherwise install a pres-
sure reducer upstream of the softener;
the internal diameter of water entrance
2.1
WATER
SPECIFICATIONS
Monitoring of water recipe to keep it within
required levels and maintenance of filtration
system is the user's responsibility.
Failing to meet and maintain water at the follow-
WARNING
ing levels will void the entire warranty:
WARNING
2
2.2
The machine must always be protected by an
3
automatic omnipolar switch of suitable
power with contact openings of equal dis-
tance or more than 3mm.
Victoria Arduino is not liable for any damage
to people or objects due to not observing
Fig. 6
current security measures.
Prior to connecting the machine to the electrical
mains, assess that the voltage shown on the
machine's data plate corresponds with that of
the mains.
If it does not, carry out the connections on the
basis of the available electrical line, as follows:
water to be cold.
ELECTRICAL
SPECIFICATIONS
CAUTION
RISK OF SHORT CIRCUITS
/ 3 phases voltage + Neutral:
1 2 3 4
5
Fig. 7