Télécharger Imprimer la page

EIBENSTOCK ETR 230 Notice Originale page 23

Publicité

Les langues disponibles

Les langues disponibles

Support panels or any oversized workpiece to minimize the risk of
heel pinching and kickback. Large workpieces tend to sag under their
own weight. Supports must be placed under the workpiece near the line of
cut and near the edge of the workpiece on both sides of the wheel.
Use extra caution when making a "pocket cut" into existing walls or
other blind areas. The protruding wheel may cut gas or water pipes,
electrical wiring or objects that can cause kickback.
Use suitable detectors to determine if utility lines are hidden in the
work area or call the local utility company for assistance. Contact with
electric lines can lead to fire and electric shock. Damaging a gas line can
lead to explosion. Penetrating a water line causes property damage or may
cause an electric shock.
Safety warnings specific for sanding operations
Do not use excessively oversized sanding disc paper. Follow
manufacturers recommendations, when selecting sanding paper.
Larger sanding paper extending beyond the sanding pad presents a
laceration hazard and may cause snagging, tearing of the disc, or kickback.
Safety warnings specific for wire brushing operations
Be aware that wire bristles are thrown by the brush even during
ordinary operation. Do not overstress the wires by applying excessive
load to the brush. The wire bristles can easily penetrate light clothing
and/or skin.
If the use of a guard is recommended for wire brushing, do not allow
ny interference of the wire wheel or brush with the guard. Wire wheel or
brush may expand in diameter due to work load and centrifugal forces.
For further safety instructions, please refer to the enclosure!
Before starting the machine check the correspondence between voltage and
frequency according to the data mentioned on the identification plate. Voltage
differences from + 6 % and – 10 % are allowed.
The angle grinder is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section which
is too small could cause a considerable drop in performance and an
overheating of machine and cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
The tool is equipped with a start-up speed limiter to prevent that swift automatic
circuit breakers are unintentionally triggered.
Electrical Connection
Cross section in sq. mm
1.5
-
50 m
2.5
40 m
80 m
23

Publicité

loading