Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Logic
Definition
Configura-
tion of AUX 3
AUX 3
output.
26-37
Fixed code
FIXED CODE
Protection
Setting the
protection level
level
Serial mode
(Identifies how
board is con-

SERIAL ODE

figured in a BFT
network
connection).
Address
ADDRESS
Reversing
revers. o bst
obstacle
24-
ARGO BT A 20-35
Cross
out
Default
setting
used
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Not used
4
Not used
5
Not used
6
Not used
7
Not used
8
Not used
9
Output configured as Maintenance
17
10
Not used
11
Not used
12
Not used
13
Output configured as closed Gate Status
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
16
Output configured as open Gate Status
17
Output configured as
18
Output configured as
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memori-
zed in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by
0
repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the recei-
ver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
0
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic
setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interfe-
rence, if any.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
0
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
Identifies board address from 0 to
0
[ ___ ]
(see U-LINK OPTIONAL MODULES section)
During closure, after an obstacle is detected, the movement gets reversed for 2 seconds.
0
During opening, after an obstacle is detected, the manoeuvre gets interrupted and the automation is blocked.
0
1
Both while closing as well as opening, after an obstacle is detected, the movement gets reversed for 2 seconds.
After detecting an obstacle during closure, it re-opens completely.
2
After detecting an obstacle during opening, the manoeuvre gets interrupted and blocks the automation.
ENGLISH
Optional extras
Output 1 PROGRAMMABLE IN HEIGHT
Output 2 PROGRAMMABLE IN HEIGHT.
119
in a local BFT network connection.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Argo bt a 35

Table des Matières