Morsetto
Definizione
AUX 0 - CONTATTO
20
ALIMENTATO 24V
21
(N.O.) (1A MAX)
26
AUX 3 - CONTATTO
LIBERO (N.O.)
27
(Max 24V 1A)
50
51
52
24 Vsafe+
60
61
62
70
71
72
73
Terminal
Definition
AUX 0 - 24V POWERED
20
CONTACT (N.O.)
21
(MAX. 1A)
AUX 3 - FREE
26
CONTACT (N.O.)
27
(MAX. 24V 1A)
50
51
52
24 Vsafe+
60
Common
61
62
70
Common
71
72
73
Borne
Définition
AUX 0 - CONTACT
20
ALIMENTÉ 24V (N.O.)
21
26
AUX 3 - CONTACT
LIBRE (N.O.)
(Max 24V 1A)
27
50
51
52
60
61
62
70
71
72
73
10-
ARGO BT A 20-35
Descrizione
Uscita per LAMPEGGIANTE.
Il contatto rimane chiuso durante la movimentazione delle ante.
Uscita configurabile AUX 3 - Default Uscita 2°CANALE RADIO.
CANALE RADIO MONOSTABILE / SPIA CANCELLO APERTO SCA / COMANDO LUCE CORTESIA / MANUTENZIONE / STATO CANCELLO CHIUSO /
CANALE RADIO BISTABILE / CANALE RADIO TEMPORIZZATO / STATO CANCELLO APERTO / USCITA 1 PROGRAMMABILE IN ALTEZZA / USCITA
2 PROGRAMMABILE IN ALTEZZA
24V-
Uscita alimentazione accessori.
24V+
Uscita alimentazione per dispositivi di sicurezza verificati (trasmettitore fotocellule).
Uscita attiva solo durante il ciclo di manovra.
Comune
Comune ingressi IC 1 e IC 2
Ingresso di comando configurabile 1 (N.O.) - Default START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Far riferimento alla tabella "Configurazione degli ingressi di comando".
Ingresso di comando configurabile 2 (N.O.) - Default PED.
IC 2
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Far riferimento alla tabella "Configurazione degli ingressi di comando".
Comune
Comune ingressi STOP, SAFE 1 e SAFE 2
Il comando interrompe la manovra. (N.C.)
STOP
Se non si utilizza lasciare il ponticello inserito.
Ingresso di sicurezza configurabile 1 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2 / BAR OP / BAR OP TEST / BAR
SAFE 1
8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 CL /STOP 8K2
Far riferimento alla tabella "Configurazione degli ingressi di sicurezza".
Ingresso di sicurezza configurabile 2 (N.C.) - Default PHOT.
SAFE 2
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST
Far riferimento alla tabella "Configurazione degli ingressi di sicurezza".
Description
FLASHING LIGHT output .
The contact remains closed during the movement of the leaves.
AUX 3 configurable output - Default setting MONOSTABLE RADIO CHANNEL
MONOSTABLE RADIO CHANNEL / SCA OPEN GATE INDICATOR LIGHT / COURTESY LIGHT CONTROL / MAINTENANCE / CLOSED GATE STATE /
BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL / OPEN GATE STATE / HEIGHT PROGRAMMABLE OUTPUT 1 / HEIGHT PROGRAMMABLE
OUTPUT 2
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter).
Output active only during operating cycle.
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 2 (N.O.) - Default PED.
IC 2
START E /
START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
STOP, SAFE 1 and SAFE 2 inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2 / BAR OP / BAR OP TEST / BAR
SAFE 1
8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 CL /STOP 8K2
Refer to the "Safety input configuration" table.
Configurable safety input 2 (N.C.) - Default PHOT.
SAFE 2
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST
Refer to the "Safety input configuration" table.
Description
Sortie pour CLIGNOTANT.
Le contact reste fermé pendant le mouvement des vantaux.
(1 A MAX)
Sortie configurable AUX3 – Défaut Sortie 2ème CANAL RADIO.
CANAL RADIO MONOSTABLE/VOYANT DE PORTAIL OUVERT SCA/COMMANDE DE LUMIÈRE DE COURTOISIE/ENTRETIEN/ÉTAT DE PORTAIL
FERMÉ/CANAL RADIO BISTABLE/CANAL RADIO TEMPORISÉ/ÉTAT DE PORTAIL OUVERT/SORTIE 1 PROGRAMMABLE EN HAUTEUR/SORTIE 2
PROGRAMMABLE EN HAUTEUR
24V-
Sortie alimentation accessoires.
24V+
Sortie alimentation des dispositifs de sécurité vérifiés (émetteur photocellules)
24 Vsafe+
Sortie active uniquement pendant le cycle de manœuvre.
Commun
Commun entrées IC 1 et IC 2
Entrée de commande configurable 1 (N.O.) - Défaut START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Consulter le tableau "Configuration des entrées de commande".
Entrée de commande configurable 2 (N.O.) - Défaut PED.
IC 2
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Consulter le tableau "Configuration des entrées de commande".
Commun
Commun entrées STOP, SAFE 1 et SAFE 2
La commande interrompt la manœuvre. (N.F.)
STOP
Si vous ne l'utilisez pas, laissez la barrette en place.
Entrée de sécurité configurable 1 (N.F.) - Défaut BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2 / BAR OP / BAR OP TEST / BAR
SAFE 1
8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 CL /STOP 8K2
Consulter le tableau "Configuration des entrées de sécurité".
Entrée de sécurité configurable 2 (N.C.) - Défaut PHOT.
SAFE 2
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST
Consulter le tableau "Configuration des entrées de sécurité".