BFT ARGO BT A 20 Instructions D'utilisation Et D'installation page 25

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Logic
Definition
Configuration
of EXPI1 input
on input-output
EXPI1
expansion
board.
1-2
Configuration
of EXPI2 input
on input-output
EXPI2
expansion
board.
1-3
Configura-
tion of EXPO2
output
on input-output
EXPO1
expansion
board
4-5
Configura-
tion of EXPO2
output
on input-output
EXPO2
expansion
board
6-7
(**) Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.
Aux logic= 0 - MONOSTABLE RADIO CHANNEL output.
Contact stays closed for 1s when radio channel is activated.
Aux logic= 1 - SCA GATE OPEN LIGHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIGHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 – Not used
Aux logic= 4 – Not used
Aux logic= 5 – Not used
Aux logic= 6 – Not used
Aux logic= 7 – Not used
Aux logic= 8 – Not used
Aux logic= 9 - MAINTENANCE output.
Contact stays closed once the value set for the Maintenance parameter is reached, to report that maintenance is required.
Aux logic= 10 – Not used
Aux Logic= 11 – Not used
Aux Logic= 12 – Not used
Aux logics= 13 - GATE STATUS output
Contact stays closed while gate is closed.
AUX logics= 14 - BISTABLE RADIO CHANNEL output
The contact changes status (open-closed) when the radio channel is activated
AUX logics= 15 - TIMED RADIO CHANNEL output
The contact remains closed for a programmable length of time when the radio channel is activated (output time)
If, during this time, the button is pressed again, counting starts all over again.
Aux logic= 16 - GATE OPEN ALARM output.
Contact stays closed when the gate is open.
Logic Aux=17 – Output 1 PROGRAMMABLE IN HEIGHT.
The contact closes when the door exceeds the percentage opening set in parameter "Out Prog 1"
Logic Aux=18 – Output 2 PROGRAMMABLE IN HEIGHT.
The contact closes when the door exceeds the percentage opening set in parameter "Out Prog 2"
IC logic= 0 - Input configured as Start E. Operation according to STEP-BY-STEP
IC logic= 1 - Input configured as Start I. Operation according to STEP-BY-STEP
Cross
out
Default
setting
used
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
2
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the mo-
11
vement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the mo-
12
vement stops.
13
Input configured as Phot test safety, tested photocell.
14
Input configured as Phot op test safety, tested photocell active only while opening.
15
Input configured as Phot cl test safety, tested photocell active only while closing.
16
Input configured as Bar safety, tested safety edge.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
17
movement stops.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
18
movement stops.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
3
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Not used
13
4
Not used
5
Not used
6
Not used
7
Not used
8
Not used
9
Output configured as Maintenance.
10
Not used
11
Not used
12
Not used
13
Output configured as Gate Status
16
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
16
Output configured as open gate Status
17
Output configured as
18
Output configured as
AUX output configuration
Command input configuration
ENGLISH
Optional extras
Output 1 PROGRAMMABLE IN HEIGHT
Output 2 PROGRAMMABLE IN HEIGHT.
OV. logic. External start for traffic light control.
OV. logic. Internal start for traffic light control.
ARGO BT A 20-35 - 25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Argo bt a 35

Table des Matières