Serial Ode - BFT DEIMOS ULTRA BT A 400 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Logic
Definition
Setting the
Protection
protection level
level
Serial mode
(Identifies
how board is
SERIAL
ODE
configured in
a BFT network
connection).
Address
ADDRESS
Configuration
of EXPI1 input
on input-output
EXPI1
expansion
board.
1-2
INSTALLATION MANUAL
Cross
out
Default
setting
used
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memori-
zed in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by
0
repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the recei-
ver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
0
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interfe-
rence, if any.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
0
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network with no
2
smart module (fig.R)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network with no
3
smart module (fig.R)
Identifies board address from 0 to
[ ___ ]
0
(see U-LINK OPTIONAL MODULES section)
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
1
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the mo-
*
11
vement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the mo-
*
12
vement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is switched
*
13
automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/output
*
14
expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/output
*
15
expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched
*
16
automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
*
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
17
input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
*
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
18
input, EXPFAULT1.
Optional extras
119
in a local BFT network connection.
DEIMOS ULTRA BT A 400 - DEIMOS ULTRA BT A 600 -
31