Screen Messages - ZUMEX ESSENTIAL BASIC Manuel De L'utilisateur

Masquer les pouces Voir aussi pour ESSENTIAL BASIC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

FAULT
THE MACHINE STOPS EVERY
NOW AND AGAIN
SCREEN DOES NOT DISPLAY
INFORMATION
THE MACHINE IS IN SELF-
SERVICE MODE AND WON'T
STOP OPERATING
WARNING: Any action to unblock the machine must be carried out by disconnecting it
from the mains. If, after making the checks stated here, the machine does not work, call the
technical service.

SCREEN MESSAGES

DISPLAY MESSAGE
EXCESS CURRENT
NO ORANGES
MEMORY INITIATED
CALIBRATION
POSSIBLE CAUSE
Insufficient ventilation.
Overload.
Alteration to mains systems.
Faucet not fitted or fitted
incorrectly.
Faucet well fitted: possible internal
fault.
Faucet block activated.
CAUSE
The maximum electrical
consumption level has been
exceeded for at least one second.
The motor remains on for two
minutes detecting any squeezing.
A memory error has been detected.
An incorrect calibration value has
been detected.
CORRECTION
Check that the appliance's
ventilation grilles are not blocked.
Contact your technical service.
Turn off the machine and turn it
back on again.
Fit the faucet in the manner
indicated in Fig. 11A
Contact your technical service.
Put the block in horizontal position
by pressing the faucet downwards.
CORRECTION
Turn off at mains and turn back
on again.
Put oranges back in feeder again
without and press ON.
Contact your technical service.
Calibrate (See page 18).
55

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Essential proVersatile pro

Table des Matières