SOLUTION FILTER CLEANING

1.
Drive the machine on a level floor.
2.
Ensure that the machine is off and the user key (51) has been removed.
3.
Close the detergent solution tank valve (A, Fig. 14). The valve is closed when it is in position (B) and it is open when it is in
position (C).
4.
Remove the transparent cover (D) and the gasket (E), then remove the filter strainer (F). Wash and rinse them, then refit them
carefully onto the filter support (G).
5.
Open the valve (A).

MACHINE TRACKING ADJUSTMENT

The machine tracking (straight movement) may vary according to the type of floor to be cleaned and depending on whether the
brush or the pad is used.
If it is difficult to keep the machine moving straight as it tends to pull to the left or to the right with the brush deck lowered and during
cleaning, adjust the handwheel (35) by turning it clockwise or counter-clockwise to correct this pull and obtain a generally neutral
straight-ahead movement.