1.4.14.4 Installation and operating conditions
The motors may be used only in ambient temepratures up to 50 °C.
l
If the front flange is coated, the tolerance class N is not guaranteed.
l
Motors with flanges without wash-outdown coating: The flange surface must be protected by
suitable assembly against the influence by cleaning agents.
1.4.14.5 Cleaning plan
Recommended cleaning plan (short form) with tested cleaning agents:
Flushing with water (40 °... 50 °C)
Flushing with low pressure. From top to bottom in the direction of the drain. Clean the drain.
Foam cleaning
Foaming from top to bottom.
Alkaline:
Acid:
Temperature:
Disinfection
Spraying with wayer (40 °... 50 °C) with low pressure. From top to bottom.
Spray disinfection:
Foam disinfection:
P3-topactive LA or P3-topax 66 (2-5%, 15 min daily)
P3-topax 56 (2%, if necessary 15 min)
cold up to 40 °C
P3-topax 91 (1-2%, if necessary 30-60 min)
P3-topactiv DES (1-3%, if necessary 10-30 min)