Servicing the generator

10
Servicing the generator
10.1
Maintenance table
!
WARNING!
Only have maintenance work carried out by specialist personnel
who are familiar with the relevant regulations. Inadequate mainte-
nance may cause serious hazards.
I
NOTE
Have the following maintenance work performed at regular inter-
vals or after the specified number of operating hours, whichever
is sooner.
Interval
Inspection/maintenance
➤ Change the oil (chapter "Changing the oil" on page 23).
In the first
month or after
50 hours
➤ Check and clean the air filter (chapter "Servicing the air filter"
Every 3 months
or every
50 hours
Every
➤ Change the oil (chapter "Changing the oil" on page 23).
250 hours
➤ Clean the motor's cooling devices.
➤ Check the valves.
➤ Check if the screws are intact and firmly tightened.
➤ Replace the fuel filter (chapter "Changing the fuel filter" on
Every
500 hours
➤ Replace the air filter (chapter "Servicing the air filter" on
➤ Clean the oil filter.
Once a year
or every
➤ Check the diesel oil supply lines.
1000 hours
The following must be carried out by a HATZ authorised retailer
or Dometic skilled personnel:
➤ Check the fuel injection pump.
➤ Check the vibration damper.
22
on page 25).
page 24).
page 25).