Operating the generator
Display message
Description
SHORT CIRCUIT
The consumers cause a short
circuit at the output.
OVER TEMPERATURE
Overheating
LOW POWER ENGINE
The inverter supply voltage
has dropped.
RESTART GEN?
Message appears after the
generator has stopped due to
overheating.
GEN CAL
Message appears when the
generator is started up; it
shows the calibration phase
which takes place before
each start-up. The generator
does not supply any voltage.
GEN WAIT
Message appears while you
are waiting for the generator
to start again.
GEN ON
The generator is operating
normally.
GEN OFF
20
Generator behaviour
The inverter switches off,
therefore no voltage is sup-
plied but the engine carries
on running until it goes off.
The inverter switches off so
no voltage is supplied to cool
the generator, but the engine
carries on running.
The generator stops.
The generator is switched off. Press the start button to
The generator is running but
does not supply any voltage.
The generator is switched off. Wait until the message has
Normal mode
The generator is in stand-by
and can be started.
TEC30D EV
Measures
Check the connected
consumers. Stop the genera-
tor and restart it.
Leave the engine to cool
down for a few minutes. Stop
the generator and restart it.
Reduce the connected load
and start the generator again.
restart the generator.
Wait a moment.
disappeared then attempt
ignition again.