Nilfisk Advance SC6000 36C Mode D'emploi page 25

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CHARGING GEL/AGM (VRLA) BATTERIES
Charge the batteries each time the machine is used or when the Battery Charge Level Indicator (C3) is reading less than full.
WARNING!
Charge batteries in a well-ventilated area. If battery acid makes contact with your skin, À ush the affected area with water for 5
minutes and seek medical attention.
Do not smoke while servicing the batteries.
When Servicing Batteries...
*
Remove all jewelry
*
Do not smoke
*
Wear safety glasses, rubber gloves and a rubber apron
*
Work in a well-ventilated area
*
Do not allow tools to touch more than one battery
terminal at a time
*
ALWAYS disconnect the negative (ground) cable ¿ rst
when replacing batteries to prevent sparks.
*
ALWAYS connect the negative cable last when installing
batteries.
CAUTION!
Your valve regulated lead acid (VRLA) battery
will deliver superior performance and life ONLY
IF IT IS RECHARGED PROPERLY! Under or
overcharging will shorten battery life and limit
performance. Be sure to FOLLOW PROPER
CHARGING INSTRUCTIONS! DO NOT ATTEMPT
TO OPEN THIS BATTERY! If a VRLA battery
is opened, it loses its pressure and the plates
become oxygen contaminated. THE WARRANTY
WILL BE VOIDED IF THE BATTERY IS OPENED.
If your machine shipped with an onboard battery charger
do the following:
1
Turn the machine off at the Power Switch (B).
2
See Figure 12. Raise the steering column to the full upright position. Tip the seat forward and engage the Seat Prop Rod (9) for battery, charger access and
proper ventilation.
3
Unwind the electrical cord for the onboard charger and plug it into a properly grounded outlet. Refer to the OEM product manual for more detailed operating
instructions. While AC power is applied to the onboard charger all machine functions are disabled.
4
The Battery Charge Status Indicator (C19) will begin showing the batteries' state of charge. This indicates that the charging cycle has begun. As the
charging cycle continues, the battery charge level will ¿ ll in.
5
When the Battery Charge Status Indicator (C19) is completely ¿ lled, the machine senses fully charged batteries, however the charging process may not be
complete. Rely on the status lights on the Charger (12) (and its OEM manual) to verify when the batteries are completely charged. This may take several
hours depending upon the condition of the batteries before charging.
6
After charging is complete unplug the charger and wind up the Cord (12A). Wait at least 10 seconds before turning on the machine after unplugging the
charger.
If your machine shipped without an onboard battery charger do the following:
1
Turn the machine off at the Power Switch (B).
2
See Figure 12. Raise the steering column to the full upright position. Tip the seat forward and engage the Seat Prop Rod (9) for battery access and proper
ventilation.
3
Disconnect the batteries from the machine and push the connector from the charger into the Machine Battery Connector (10). Follow the instructions on the
battery charger. SERVICE NOTE: Make sure you plug the battery charger into the connector that attaches to the batteries.
IMPORTANT: Make sure you have an appropriate charger for use on Gel cell batteries. Use only "voltage-regulated" or "voltage-limited" chargers.
Standard constant current or taper current chargers MUST NOT be used. A temperature-sensing charger is recommended, as manual adjustments are
never accurate and will damage any VRLA battery.
4/2016
INSTRUCTIONS FOR USE
12A
12
56091161 - SC6000
ENGLISH - A
FIGURE 12
10
9
C19
A - 25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Advance sc6000 40dAdvance sc6000 34d561160005611600156116002

Table des Matières