42. Push Prg Button and with "Arrows up-down"
write the PWD 0066 then push
43. Select CONFIGURATION (Driver B) and
push
13. At
page
5
of
CONFIGURATION and push
44. Move to DISABLED and confirm by pushing
45. Push
"Esc"
CONFIGURATION/SETTING
46. Select with "Arrows up-down" REGULATION
(Driver B) and move to page 1 of 11
47. Select Superheat setpoint and push
48. With "Arrows up-down" move to 8K and push
49. At page 1 of 11 select Valve opening at
start-up and push
50. With "Arrows up-down" move to 50% and
push
51. With "Arrows up-down" move to page 5 of 11,
select PID integral time and push
52. With "Arrows up-down" move to 100 s and
push
11
select
RELAY
to
leave
the
53. With
"Arrows
derivative time and push
54. With "Arrows up-down" move to 5.0 s and
push
55. With "Arrows up-down" go to page 6 of 11,
select LowSH protect. threshold and push
56. With "Arrows up-down" select 3K and
57. With "Arrows up-down" move to page 6 of 11
LowSH protect. integral time and push
58. With "Arrows up-down" select 10.0 s and
push
59. With "Arrows up-down" go to page 7 of 11,
select LOP protection threshold and push
60. With "Arrows up-down" move to -38°C and
push
61. With "Arrows up-down" move to LOP
protection integral time and push
62. With "Arrows up-down" move to 5.0 s and
push
63. Push "Esc" to leave the REGULATION
16
up-down"
move
to
PID

Publicité