Language Selection; General Management Of All Source - ECOFOREST ecoSMART e-manager Manuel D'utilisation

Masquer les pouces Voir aussi pour ecoSMART e-manager:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.1. Language selection

6.2. General management of all source

Language
Used to select the language of the heat pump controller.
Language
4. Used to enable the language selection screen that appears on launching the
controller.
5. Used to adjust the display time of the language selection screen on launching the
controller.
Source management
Used to select the source management type between "DT Sources" and "T return":
1. DT Sources: the e-source manages sources to maintain a fixed DT. DT is the difference
between the outlet temperature and the inlet temperature.
2. T return: the e-source manages sources to maintain a specific inlet temperature.
DT Sources
Only if "DT Sources" has been selected. Used to select the value of the temperature
difference between target outlet and inlet.
T return
Only if "T return" has been selected. Used to select an inlet temperature setpoint to be set
in heating mode and another in cooling mode.
Source on/off
1. Used to configure the temperature differential and the time to start up a brine source.
2. Used to configure the temperature differential and the time to turn off a brine source.
57
ecoSMART e-source
user, installer and technical service manual

Publicité

Table des Matières
loading

Table des Matières