Dometic TEC 29 Notice D'utilisation page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
TEC29, TEC29LPG
8.5
Stopping the generator
➤ Stop the generator with the on/off switch (fig. 3 2, page 4).
If the generator does not stop: switch it off with the main switch (fig. 2 1,
page 4).
8.6
Display messages
Display message
Description
LOW BATTERY
The battery voltage has fallen
below the minimum value for
starting up (9V).
OIL CHANGE
The number of prescribed
operating hours has been
reached for changing the
engine oil.
NO FUEL
The fuel in the tank is in
reserve.
OIL ALERT
Insufficient engine oil.
GENERATOR ALERT!
General alarm message
Example: The control ring on
the throttle valve of the carbu-
rettor (stepper motor) is
faulty.
OVERLOAD!
The consumers generate an
overload at the output.
SHORT CIRCUIT
The consumers cause a short
circuit at the output.
EN
Generator behaviour
The generator does not start.
The generator continues to
run.
The generator continues to
run.
The generator stops.
The generator stops.
The inverter switches off,
therefore no voltage is sup-
plied but the engine carries
on running until it goes off.
The inverter switches off,
therefore no voltage is sup-
plied but the engine carries
on running until it goes off.
Operating the generator
Measures
Charge the battery.
Change the oil (see chapter
"Changing the oil (fig. 6,
page 6)" on page 26), then
restart the generator by
pressing and holding down
the start button.
Refuel.
Fill up with oil (see chapter
"Checking the oil level" on
page 21).
Check the system by referring
to the troubleshooting table.
If the problem persists, con-
tact the manufacturer's
branch office in your country
(addresses on the back
page).
Reduce the connected load
and start the generator again.
Check the connected con-
sumers then start the genera-
tor again.
19