9.
OPTION: MOUNTING
BRACKET
for two inductive proximity
switches M12 x 1
The option makes it possible to adapt two inductive proximity switches
M12 x 1 (for example Turck or Balluf) for flush installation on the
actuator. The upper and lower end positions of the actuator are
recorded. The target is the switch cam. The proximity switches are not
included in the scope of supply.
9.1.
Actuator size D (50)
Fig. 13: Actuator D (50)
22
A Transparent cap
A
B Optical position indicator
C
C Actuator cover
B
D Spindle extension
D
1
Connection
English
Types 2100, 2101, 2103
Option:MountingBracket
9.1.1. Tasks before Installation
DANGER!
Risk of injury from high pressure!
• Before making alterations to the devices, switch off the pressure
and vent the lines.
Interrupt the flow of medium.
Switch off the pilot air.
Empty the valve body.
Unscrew the transparent cap Ⓐ from the actuator cover Ⓓ.
DANGER!
Risk of injury from high pressure!
Without the transparent cap, the actuator blows freely upward
when the pilot pressure is applied to the wrong connection.
• Apply the pilot pressure for control functions A and I only on
connection 1.
Control functions A and I:
To remove the optical position indicator Ⓑ, move the actuator to
the upper end position:
Apply the pilot pressure to connection 1
(one pressure pulse is sufficient for control function I).
Unscrew the optical position indicator Ⓑ from the spindle
extension Ⓓ.