• Check the alignment of all moving parts, any bro-
ken or fastening parts, and any other conditions
which may impede proper operation. Any dam-
aged part must be repaired or replaced by a spe-
cialist immediately.
• Do not use the machine if a switch cannot be
switched on and off properly.
m Attention! Before the start of operation, check
the deployment location for hidden electrical lines,
gas pipes and water pipes using a cable detector.

8. Operation

• Only use faultless devices.
• Make all machine settings with the machine
switched off.
• Never leave the machine unattended when it is
running.
• When shutting down, only leave the machine after
it has come to a complete standstill.
• Always switch the machine off before unplugging
the mains plug.
• Always unplug the mains plug. Never pull the plug
out of the socket using the cable.
• Maintain and clean the device at regular intervals.

9. Commissioning

Inserting the chisel Fig. 2
1. Always clean the chisel before inserting it and
lightly grease the shaft.
2. Pull out the locking bolt (8) up to the stop, rotate it
180° and release.
3. Insert the chisel into the tool receiver (6) and push
it up to the stop.
4. Pull out the locking bolt (8) again, rotate it 180°
and release.
5. Check the locking mechanism on the tool.
Removing the chisel
Pull out the locking bolt (8) up to the stop, rotate it
180° and release and remove the chisel.
Additional handle Fig. 3
For safety reasons, only use the demolition ham-
mer with the additional handle!
1. The additional handle (5) allows the user to main-
tain a firm hold when using the demolition ham-
mer.
2. The additional handle (5) can be turned into any
arbitrary position.
3. To do this, loosen the screw (9).
4. Now turn the additional handle (5) into a comfort-
able and safe working position and tighten the
screw (9) again firmly.
20 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Switching on/off (fig. 4)
Switching on: Press the operating switch (2).
Switching off: Release the operating switch (2).
Continuous operation: Press the operating switch (2)
and lock with the locking switch (10). Stopping con-
tinuous operation: Tap the operating switch (2).

10. Operating / working notes

m Attention! For your safety, the machine may
only be held by the two handles (3 and 5, Fig. 1)!
This avoids the risk of an electric shock when chisel-
ling in the event contact is made with lines.
Always keep chisel tools sharp.
Attention:
• Only work with low pressure when chiselling.
• Too much pressure puts unnecessary strain on the
motor.
• Sharpen chisels in good time and replace if nec-
essary.
Dust/chip extraction
Dusts from materials such as paint containing lead,
some types of wood, minerals and metal can be
harmful to health. Touching or inhaling the dust can
cause allergic reactions and/or respiratory diseases
in the user or persons in the vicinity.
Certain dusts such as oak or beech dust are con-
sidered carcinogenic, especially in combination with
additives for wood treatment (chromate, wood pre-
servatives). Material containing asbestos may only
be processed by specialists.
• Make sure that the work area is well-ventilated.
• It is recommended to wear respirators with filter
class P2.
Observe the regulations for the materials to be pro-
cessed applicable in your country.

11. Electrical connection

The electrical motor installed is connected and
operational. The connection complies with the
applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.