9) Alarm E8: Level alarm
A water level 10 cm above the established
height is detected: the cycle is aborted and
the buzzer is actuated. To remove this alarm,
just switch the machine off and then on again
or else, 5 minutes into the alarm, this is
automatically removed and the door is
unlocked. Of course, if when the machine is
switched back on alarm causes are still there,
the display will highlight this condition. The
cause of this alarm is surely the level probe.
ATTENTION, this fault can also be caused
by the use of foamy soap.
10) Alarm E9: Out-of-balance alarm
When this alarm status occurs, the step in
progress is aborted but the cycle is not
cancelled. The motor is disenergised for 200
or 90 seconds for high-speed spin and low-
speed spin respectively. Then a distribution
step intervenes for 90 seconds in order for
the laundry to be spread correctly.
Alarms occurring during intermediate spin
are not displayed: after distribution, the cycle
skips the spinning step and proceeds.
Conversely, alarms intervening during final
spin blink E9: after distribution, the machine
makes further spinning attempts, up to a
maximum of 15 and if it still fails to spin, the
alarm sign E9 is lit continuously, the buzzer
is actuated and the cycle is aborted. The
alarm is called off only when the machine is
switched off and then on again, or else, 5
minutes into the alarm, this is automatically
removed and the door is unlocked. Of course,
if when the machine is switched back on
alarm causes are still there, the display will
highlight this condition.
Alarm causes may be an incorrect laundry
load (too little or too big), unlevel machine
positioning or dampers worn out through
repeated incorrect loads.
11) Alarm E0: Motor overload cutout
In case of motor fault, i.e. overheating,
misconnection, etc., the motor goes to idle
and the message E0 is lit on the display.
When the motor is put to idle it waits for
150sec. After this safety time the machine
performs a distribution step and then makes
a new attempt. If after the maximum number
of attempts (five) the alarm is triggered
again, the cycle is aborted, the display flashes
the alarm and the buzzer is heard for 5
minutes on end. After that the system will be
reset automatically.
Measures to be taken in case of a
voltage drop
If a voltage drop longer than 3 sec. occurs
during a wash cycle, on being re-energised
all the luminous devices the machine is
fitted with (wash step LEDS, time, cycle and
temperature DISPLAYS) are reset: they flash
for one minute with all functions disabled.
As soon as normal work conditions are
restored the cycle will be resumed from the
step that was underway when the voltage
drop occurred and displays will resume their
normal functions. Conversely, if the door is
open when the machine is re-energised, the
cycle will be aborted.
ATTENTION If the ON - OFF switch is
actuated to turn machine off after the
cycle has been started, the machine will
behave as if a voltage drop has occurred.
ATTENTION: WHEN ONE OR MORE
ALARMS APPEAR ON DISPLAY
DURING MACHINE OPERATION, IN
ORDER
TO
AVOID
DAMAGE, REMOVE MISFUNCTION
SOURCES (IF POSSIBLE) BEFORE
STARTING A NEW CYCLE OR
CONTACT THE AUTHORISED AFTER-
SALES SERVICE OR DEALER.
7.8 INFORMATION ABOUT SPECIAL
MEASURES FOR USE AND
PROTECTION
When carrying out the first cycle, verify the
following:
- Soap dispensers must stay clean:
dispenser A after taking in pre-wash water;
dispenser B after taking in wash water;
dispenser C after taking in water for the
last rinse.
- Remove all soap made solid during machine
lay up.
- Perform a 90°C cycle to remove all
manufacturing residues.
- The operator must be able to check soap
compartments with ease. Place a platform if
necessary.
- Make certain that laundry trolleys are lower
than the door bottom edge.
- If need be, mount appropriate bumpers to
prevent trolleys from hitting and damaging
the door.
- Never open soap compartments when the
machine is taking in water or is heating.
7.9 ORDINARY MAINTENANCE
(to be carried out by the user)
BEFORE ANY MAINTENANCE OR
CLEANING OPERATIONS, CHECK
THAT THE WALL CUTOFF SWITCH
IS OFF AND THE HOT WATER, COLD
WATER AND STEAM TAPS ARE
CLOSED (THE LATTER APPLIES TO
STEAM-HEATED MACHINES ONLY).
THE DRUM MUST BE STILL AND
DRAINED AND THE TEMPERATURE
INSIDE MUST NOT EXCEED 40
The machine requires no special
maintenance, thanks to its ergonomic design
and to the use of very reliable, first-quality
parts.
Periodically clean the external panels with a
damp cloth. Never use inflammable or
abrasive products and rub in the direction of
the satin-finish.
Always keep forced-cooling slots and
openings free from dust (the fan sucks fresh
air from the room), which are on the rear of
the machine, where the speed changer is
housed.
21
NEVER WASH THE APPLIANCE
USING WATER JETS.
BEFORE TURNING THE MACHINE
ON BY THE CUTOFF SWITCH ON
THE WALL, PUT ALL THE PANELS
REMOVED BACK IN PLACE.
INSTRUCTIONS FOR
MAINTENANCE AND
FURTHER
REPAIR PERSONNEL
8. SCHEDULED MAINTENANCE
AND ORDERING SPARE PARTS
8.1 REMOVE THE LID
To reach the machine electrical parts, take
off the screws fastening the lid to the back
panel and the soap dispenser. Then lift the
rear part of the lid and pull it to the front by
approximately 5 cm.
BEFORE TURNING THE MACHINE
ON AGAIN BY THE WALL CUTOFF
SWITCH, PUT ALL THE PANELS
REMOVED BACK IN PLACE.
8.2 TROUBLESHOOTING
If the machine does not work, check the
following:
- the main cutoff switch on the wall is on and
the machine is getting current;
- the door is closed;
- the green start push-button has been pressed.
- the hot water, cold water and steam taps are
open (the steam tap only for steam-heated
machines).
If the fault is not due to any of the above
causes, call the authorised after-sales service
or your dealer (see last page of this booklet).
8.3 SAFETY DEVICES
- Door microswitch disconnects the auxiliary
circuit from the power mains and so stops
the appliance.
- Motor overload cutout that cuts off power
to the motor winding.
- Air-break system in the soap dispenser,
which avoids pollution of the water mains in
case of a depression.
- Normally open drain valve, which enables
safe door manual opening.
- Tilt switch that avoids mechanical damage
°
C.
in the event of irregular loads.
8.4 PERIODIC MAINTENANCE (to be
carried out by the technical personnel)
All maintenance operations must be carried
out by the authorised after-sales service or
by qualified personnel.
BEFORE ANY MAINTENANCE OR
CLEANING OPERATION, CHECK
THAT THE WALL CUTOFF SWITCH
IS OFF AND THE HOT WATER, COLD
WATER AND STEAM TAPS ARE
CLOSED (THE LATTER APPLIES TO
STEAM-HEATED MACHINES ONLY).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wfec 11Wfec 18

Table des Matières