Knick 830 R Mode D'emploi page 108

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

S.CON Menu
min / max
E-108
The S.CON menu is only displayed when
the indicator is equipped with Option 290
or 291.
• Activate parameter mode.
• Hold down the key for 2 sec.
• Select S.CON menu and confirm.
The S.CON menu is available for the min
and the max contact.
The parameter-setting sequence is identi-
cal for both menus. Here, it is only shown
for the min contact.
Setting the Limit Value (Setpoint)
• Set min limit and confirm.
Setting the Hysteresis
• Set a hysteresis of 0 to 9,999 counts and
confirm.