Connecting Inputs/Outputs; Signal Inputs - Mitsubishi Electric ecodan EHPT Série Manuel D'installation

Masquer les pouces Voir aussi pour ecodan EHPT Série:
Table des Matières

Publicité

5
System Set Up

5.2 Connecting inputs/outputs

TBO.1
1
2
1
3
CNP1
4
(WH)
3
5
6
1
1
CNP4
TBO.2
1
(RD)
3
2
SW5
3
4
5
8
1
6
1
CNV1
3
TBO.3
1
(WH)
2
5
SW4
3
4
6
1
5
6
7
SW3
8
TBO.4
1
8
2
1
3
4
5
SW2
6
7
8
8
1
CNIH
1
(OG)
3
1
1
SW1
CNBC
CNBHT
(GY)
(BK)
3
3
1
8
3
CNBH
(WH)
5
en
7
5 4 3 2 1
5 4 3 2 1
5 4 3 2 1
8 7
6
8 7
6
8 7
6
TBI.1
TBI.2
TBI.3
<Figure 5.2.1>

Signal inputs

Name Terminal block Connector Item
IN1
TBI.1 7-8
IN2
TBI.1 5-6
IN3
TBI.1 3-4
IN4
TBI.1 1-2
IN5
TBI.2 7-8
IN6
TBI.2 5-6
IN7
TBI.2 3-4
IN8
TBI.3 7-8
IN9
TBI.3 5-6
IN10
TBI.2 1-2
IN11
TBI.3 3-4
IN12
TBI.3 1-2
INA1 TBI.4 1-3
CN1A
*1. Set the ON/OFF cycle time of the room thermostat for 10 minutes or more; otherwise the compressor may be damaged.
*2. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may be reduced.
*3. To turn on the boiler operation, use the main remote controller to select "Boiler" in "External input setting" screen in the service menu.
*4. Connectable electric energy meter and heat meter
● Pulse type
● Pulse duration
● Possible unit of pulse
Those values can be set by the main remote controller. (Refer to the menu tree in "Main remote controller".)
*5. As for the SG ready, refer to "5.5 Smart grid ready".
Thermistor inputs
Name
Terminal block Connector
TH1
CN20
TH2
CN21
THW1
CNW12 1-2 Thermistor (Flow water temp.)
THW2
CNW12 3-4 Thermistor (Return water temp.)
THW5A
CNW5 1-2
THW5B
CNW5 3-4
THW6
TBI.5 7-8
THW7
TBI.5 5-6
THW8
TBI.5 3-4
THW9
TBI.5 1-2
THWB1 TBI.6 7-8
THW10 TBI.6 5-6
Ensure to wire thermistor wirings away from the power line and/or OUT1 to 16 wirings.
*1. The maximum length of the thermistor wiring is 30 m.
The length of the optional thermistors are 5 m. If you need to splice and extend the wirings, following points must be carried out.
1) Connect the wirings by soldering.
2) Insulate each connecting point against dust and water. Stranded wire should be processed with insulation-covered bar terminal (DIN46228-4 standard
compatible type).
17
1
CN01
3
(BK)
5
F2
F1
1
CN3C
(BU)
3
LED1
1
CNPWM
(WH)
3
1
CN851
(BK)
8
1
CNRF
(WH)
LED2
5
1
CN105
(RD)
LED3
5
1
CNIT
(BU)
5
CN22
1
(BU)
2
1
SW6
LED4
CN108
5
TAB1
CN401
CN1A
CNW5
CNW12
CN21
CN20
(WH)
(WH)
(BU)
(RD)
(YE)
(RD)
1
1
1
1
1
1
2
3
4
4
4
4
5 4 3 2 1
5 4 3 2 1
5 4 3 2 1
8 7
6
8 7
6
8 7
6
TBI.6
TBI.4
TBI.5
Room thermostat 1 input *1
Flow switch 1 input
Flow switch 2 input (Zone1)
Demand control input
Outdoor thermostat input *2
Room thermostat 2 input *1
Flow switch 3 input (Zone2)
Electric energy meter 1
Electric energy meter 2
Heat meter
Smart grid ready input
Flow sensor
Voltage free contact for 12 VDC detection by FTC (TBI.2 1pin ,TBI.3 5 and 7 pins have a positive voltage.)
Minimum ON time: 40 ms
Minimum OFF time: 100 ms
0.1 pulse/kWh
1
pulse/kWh
100 pulse/kWh
1000 pulse/kWh
Item
Thermistor (Room temp.) (Option)
Thermistor (Ref. liquid temp.)
Thermistor (DHW tank upper water temp.)
Thermistor (DHW tank lower water temp.)
Thermistor (Zone1 flow water temp.) (Option) *1
Thermistor (Zone1 return water temp.) (Option) *1
Thermistor (Zone2 flow water temp.) (Option) *1
Thermistor (Zone2 return water temp.) (Option) *1
Thermistor (Boiler flow water temp.) (Option) *1
Thermistor (Mixing tank water temp.) (Option) *1
Wiring specification and local supply parts
Item
Name
Signal input
Signal input
function
wire
Switch
Note:
Stranded wire should be processed with insulation-covered bar terminal
(DIN46228-4 standard compatible type).
OFF (Open)
ON (Short)
Refer to SW2-1 in <5.1 DIP Switch Functions>.
Refer to SW2-2 in <5.1 DIP Switch Functions>.
Refer to SW3-2 in <5.1 DIP Switch Functions>.
Normal
Heat source OFF/ Boiler operation *3
Standard operation
Heater operation/ Boiler operation *3
Refer to SW3-1 in <5.1 DIP Switch Functions>.
Refer to SW3-2 in <5.1 DIP Switch Functions>.
*4
*5
10
pulse/kWh
Optional part model
PAC-SE41TS-E
PAC-TH011-E
PAC-TH011-E
PAC-TH012HT-E(5 m)/
PAC-TH012HTL-E(30 m)
Model and specifications
Use sheathed vinyl coated cord or cable.
Max. 30 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire 0.13 mm² to 0.52 mm²
Solid wire: ø0.4 mm to ø0.8 mm
Non-voltage "a" contact signals
Remote switch: minimum applicable load 12 V DC, 1 mA

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières