Scope Of Delivery; Installation - T.I.P. Maxima 350 IPX DUO Mode D'emploi

Pompe submersible pour eaux usées
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Model
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Min. self-priming level (A)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced outlet.
The values between brackets refer to the illustrations given at the end of these operating instructions.
2)

4. Scope of delivery

The scope of the delivery of this product includes:
One pump with connection cable, a connection bend with union nut, a multi dimensional
connector, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the
application, additional accessories may be necessary (please refer to the chapters titled
"Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the
packing materials in an environmental-friendly manner.

5. Installation

5.1.
General installation information
During the entire process of installation, the device must not be connected to
the electrical mains.
The pump and the entire connection system have to be protected from frost.
All connection lines have to be perfectly tight since leaking lines may affect the performance
of the pump and cause considerable damage. If required, please use a suitable sealant to
make the installation airtight.
When tightening threaded connections, please do not apply excessive force which may
cause damage.
14
2)
2)
Fig. 1
Maxima 350 IPX DUO
30, evenly distributed
10 m
H07RN8-F
~ 7.0 kg
100 mm // 125 mm
1 mm // 35 mm
140 – 240 mm // 175 - 275 mm
240 – 140 mm // 275 - 175 mm
19.8 x 16.9 x 39.1 cm
30274
3

Publicité

Table des Matières
loading

Table des Matières