Qlima Ronda 80 Manuel D'utilisation page 167

Masquer les pouces Voir aussi pour Ronda 80:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
Wooden
Auger is blocked
pellets are not
reaching the
combustion
chamber
Auger motor is damaged
The hopper is empty
The fire has a
The exhaust/flue/chimney
weak, orange
is blocked
flame, pellets
are not burn-
The brazier is dirty
ing properly
There are internal ob-
and/or the
structions in the stove.
glass becomes
Smoke extractor is dam-
black too
aged.
quickly.
Wooden pellets are not
of a good quality.
The stove has not been
set up properly.
Room air recir-
Electronic printed circuit
culation blow-
board is defective.
er continues to
run when the
stove is cold.
Ash on the
Flue pipes are not air-
floor around
tight
the stove
Broken, worn or dam-
aged door seal
Stove in con-
The room temperature
stant mode,
desired by the user has
the display
been reached
shows: "Eco"
Display shows
No error. The stove re-
"SERV"
quires a service every 900
hours of operation. The
stove will simply continue
to work.
Unplug the stove at the mains socket. Re-
move the protective grill from the hopper
and clean the hopper. Carefully clean the
visible parts of the auger. Refit the pro-
tective grille and start again. Contact a
Qlima-approved technician if the problem
persists.
Replace the motor. Only to be done by a
Qlima-approved technician
Fill the pellet hopper.
Have the exhaust/flue/chimney cleaned im-
mediately by an approved chimney sweep.
Contact an approved chimney sweep.
Clean the brazier
The stove requires maintenance. Only to
be done by a Qlima-approved technician
Wooden pellets are able to burn thanks
to the natural draw of the flue. Have the
blower replaced immediately as it can be
detrimental to your health. Only to be
done by a Qlima-approved technician.
Try better quality pellets
Set up the stove. Only to be done by a
Qlima-approved technician
Replace the printed circuit board Only to
be done by a Qlima-approved technician
Only to be done by an approved flue
fitter: Flues that are not airtight can harm
your health. Seal the pipe fitting immedi-
ately (use Loctite 598 or equivalent prod-
uct) and/or replace the pipes.
Replace the seal. Only to be done by a
Qlima-approved technician
This is not an error. The stove is working in
eco mode. This mode can be changed with
the remote control
The stove requires a service. Contact a
Qlima-approved service technician. The
technician will carry out a service on the
stove and reset the notification.