General

Thermo-Finisher
food finishers are shipped with most
®
components installed and ready for operation. The following
installation instructions must be performed before connecting
electricity and operating the unit.
WARNING
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install the proper voltage
and size electrical receptacle.
• Units supplied without an electrical cord and plug
require a hardwired connection to the on-site electrical
system. Connection must be properly grounded and
of the correct voltage, size, and configuration for the
electrical specifications of the unit. Contact a qualified
electrician to determine and install the proper electrical
connection.
• Unit must be installed by a qualified electrician.
Installation must conform to all local electrical codes.
Installation by unqualified personnel will void the unit
warranty and may lead to electric shock or burn, as
well as damage to unit and/or its surroundings.
• Unit is not weatherproof. Locate unit indoors where
ambient air temperature is a minimum of 70°F (21°C)
and a maximum of 104°F (40°C).
FIRE HAZARD:
• For corded units: To reduce the risk of fire, the appliance
is to be installed in non-combustible surroundings
only, with no combustible material within 18" (457 mm)
of the sides, front, or rear of the appliance or within
40" (1016 mm) above the appliance. The appliance
is to be mounted on surfaces of noncombustible
construction with noncombustible flooring and surface
finish and with no combustible material against the
underside, or on noncombustible slabs or arches have
no combustible material against the underside. Such
construction shall in all cases extend not less than 12"
(305 mm) beyond the equipment on all sides.
• For hardwired units: Do not install closer than 3"
(76 mm) from any side wall. Install only over a non-
combustible surface, see installation instructions.
CAUTION
Transport unit in upright position only. Failure to do so
may result in damage to unit or personal injury.
Form No. TFWMM-0817
1. Remove the unit from the carton. Two or more people are
required for this step.
2. Remove tape, protective packaging, and literature from all
surfaces of the unit.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
NOTE: Do not plug in or hardwire the unit until wall mounting
installation is complete.
3. Refer to the "Installing the Unit" procedure in this section.
4. For corded units, plug the unit into a properly grounded
electrical receptacle of the correct voltage, size, and plug
configuration. See the SPECIFICATIONS section for
details.
5. For non-corded units, have a qualified electrician
install a hardwired connection between the unit and
the on-site electrical system. The connection must be
properly grounded and of the correct voltage, size, and
configuration. See the SPECIFICATIONS section for
details.
7

INSTALLATION