Télécharger Imprimer la page

Detecting Faults And Problems And Security Advices - ZUMEX SPEED SELF-SERVICE Manuel De L'utilisateur

Masquer les pouces Voir aussi pour SPEED SELF-SERVICE:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MANUAL SpeedSelf&Cooler 26/10/07 12:24 P gina 20
12
11
10
Index
Reference
1
DEPOSIT COVER
13.020.000
2
260.0004.000
FIXING PLATE
260.0005.000
3
PUMP COVER
260.0009.000
4
TAP PISTON
5
260.0010.000
TAP JOINT
6
260.0001.000
JUICE DEPOSIT
7
260.0011.000
LEVER
DRIP TRAY FILTER
8
260.0007.000
9
260.0008.000
DRIP TRAY
10
260.0024.000
BALANCE FOOT
11
260.0003.000
DEPOSIT JOINT
12
PUMP TURBINE
260.0006.000
38
Zumex Speed Cooler Podium Dispenser
1
2
3
4
5
6
7
8
9
Description

6. DETECTING FAULTS AND PROBLEMS AND SECURITY ADVICES

• ALL MODELS
FAULT
POSSIBLE CAUSE
Machine is not on
No voltage
Top is not placed correctly
The machine does not start
Faulty safety detectors
Faulty ON/OFF switch
Faulty circuit
Not enough voltage
Machine blocks often when
juicing
Faulty circuit
Drums are blocked
Oranges are blocked
Drums are not synchronized
Internal fault
Peel ejector is broken
Peel ejectors are incorrectly placed
Motor is running but drums are
Internal fault
not running
Tap is blocked
Juice has pulp or seeds
Machine stops after a short
Not enough ventilation
period of time
Too much power
• ONLY Zumex Speed Cooler Podium
FAULT
POSSIBLE CAUSE
Cooling group is disconnected
The cooling group does not cool
Cooling group is not on
the system
Temperature regulation device is not
positioned correctly
Internal fault
Level detector photocells are dirty
The machine does not start
Deposit walls are dirty
Internal fault
IMPORTANT SAFETY ADVICE
Always disconnect the machine before carrying out any action to unblock the unit.
To avoid accidents, do not start the machine without the safety detectors of the protective cover.
The cover acts on the safety detectors. The correct operation of the safety detectors must be tested periodically. Start
the machine and then remove the cover and check the machine to ensure that it stops. If the machine does not stop,
contact the Technical support service.
Do not start or use the machine if the power supply cable is damaged, contact the Technical support service.
When moving the machine and base stand (Zumex Speed Self-Sevice Podium and Zumex Speed Cooler Podium):
Unlock the front wheels of the base stand.
Never push the machine, only push the base stand. Never pull the base stand towards you.
SOLUTION
Connect it
Check the socket
Ensure it is placed correctly
Contact the Technical support service
Contact the Technical support service
Contact the Technical support service
Check voltage and see if it matches
that described in the manual
Contact the Technical support service
Eliminate blockage
Contact the Technical support service
EN
See the manual for correct placement
instructions (Fig. 7)
Contact the Technical support service
Clean the tap and ensure that both filters
of the container are placed correctly
Ensure the ventilation grids of the machine
are not blocked
Contact the Technical support service
SOLUTION
Press the push-button placed on the left
of the deposit's control lever
Check the internal connection on the
opening of the back cover of the base stand
Turn clockwise to increase cooling
Contact the Technical support service
Clean photocells
Clean the deposit
Contact the Technical support service
39

Publicité

loading

Ce manuel est également adapté pour:

Speed self-service podiumSpeed cooler podium