Signal Conditioning - HBM PW15iA Notice De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Structure and mode of operation
FMD
ASF
A
Filter
D
RUN
BRK
12
3.2

Signal conditioning

SZA
ICR
SFA
Working
Data
standard
rate
calibr.
Dosing control
Fig. 1.2
Signal conditioning
Digitization is followed by filtering, using digital filters
adjusted by the software. The ICR command changes
the output rate (measured values per second).
In the working standard calibration of the electronics (on
delivery), 0 mV/V corresponds to zero and the maximum
capacity is either 1,000,000 digits (NOV≠0), or
5,120,000 digits (NOV=0). The two parameters LDW and
LWT give you the opportunity to adapt the characteristic
curve to meet your requirements (scale curve) and you
can use the NOV command to standardize the measured
values to the required scaling value (e.g. 3000 d).
Detailed information can be found in the command docu­
mentation and in the online help for the PanelX program.
You also have the opportunity to
S switch from gross to net signals,
A4359-1.0 HBM: public
NOV, RSN
LDW, LWT
LIC
User-defined
Lineari-
scaling
zation
Coarse Flow
Fine Flow
Ready
Alarm
Gross
measured
value
TAV, TAS
Net
measured
Tare
value
PVA
Extreme
Min/
Max
values
IMD
Trigger/
Trigger
Stop
LIV
Limit
Limit
values
values
PW15iA

Publicité

Table des Matières
loading

Table des Matières