BFT VIRGO SMART BT A Instructions D'installation page 45

Automations a bras pour portails battants
Masquer les pouces Voir aussi pour VIRGO SMART BT A:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
Logic
Definition
Block pulses during
iBL TCA
TCA
Block pulses during
IBL CLOSE
closing
RAM BLOW
Hammer during
opening
C. O P
RAM BLOW
Hammer during
closing
C. C L
BLOC PER-
Stop maintenance
SIST
Closing limit switch
PRESS SWC
pressure
ICE
Ice feature
1 OT. O N
1 motor active
Reversal of the
change ot
motor time lag
OPEN IN
Open in other
OTHER DI-
direction
RECT.
Configuration of
SAFE 1
safety input SAFE 1.
72
Configuration of
SAFE 2
safety input SAFE 2.
74
Configuration of
IC 1
command input IC 1.
61
Configuration of
IC 2
command input IC 2.
62
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid
0
1
lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid lock
0
1
to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on in
the direction of the stop for approx. 3 seconds. This operation is performed every hour.
0
1
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil due
to a drop in temperature during extended pauses, such as during the night, or due to internal leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing
0
limit switch must be adjusted accurately (Fig.G Ref.B).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor inter-
0
preting this as an obstacle.
1
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the
mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing
limit switches to trip slightly earlier (Fig.G Ref.A).
0
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than
0
the value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
1
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing
cycle.
0
Both motors active (2 leaves).
0
1
Only motor 1 active (1 leaf ).
Opening: M1 starts in advance in comparison with M2 (opening time lag). (See Fig. J)
0
Closing: M2 starts in advance in comparison with M1 (closing time lag). (See Fig. J)
The pedestrian operation is performed by M1
0
Opening: M2 starts in advance in comparison with M1 (opening time lag). (See Fig. J)
1
Closing: M1 starts in advance in comparison with M2 (closing time lag). (See Fig. J)
The pedestrian operation is performed by M2
0
Standard operating mode (See Fig.J).
0
1
Opens in other direction to standard operating mode (See Fig. J)
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
0
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
9
movement stops.
6
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
10
closing, the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
11
movement stops.
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
12
movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
13
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
14
movement stops.
0
Input configured as Start E.
1
Input configured as Start I.
0
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
4
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
Optional extras
VIRGO SMART BT A
- 45

Publicité

Table des Matières
loading

Table des Matières