11

Technical data

Data
Supply voltage
Power consumption, without current limitation (max.)
Power consumption, with current limitation switched
on (max.)
Speed adjustment range (in increments of 500)
Calibration at
Speed tolerance, of set point
Speed monitoring time to nominal speed
unrestricted, with speed moni-toring switched off
Speed monitoring time up to rated speed
(detachable)
International protection
Protection class
Ambient temperature
Weight (approx.)
Range of application (wettable drilled hole diameter)
Electrical connection 8-pole circular connector M12
Inputs start signal:
All inputs have over voltage and transient protection.
Output speed OK/not OK and collision signal:
One-active, with active start signal 0 V = not OK,
24 V = OK, with inactive start signal 0 V = OK, 24 V = not OK
The output is short-circuit-proof, it is to be loaded with a max. 50 mA.
11.1

Dimensions

Fig. 10: Dimensions
one – active
Current limitation:
24 V = Start
open = On
0 V = Stop
24 V =Off
31
Technical data
Value Unit
24 ± 10% V, DC
2 A
0,8 A
4000 – 9000 rpm
4000 and 8000 rpm
± 2,5 %
0,5 s
0,5 s
55 IP
III
+10 to + 40 °C
0,4 kg
8 to 100 mm
Time limitation:
open = On
24 V = Off
417101448 Rev. 04-02.2019