10
Technical data
Data
Supply voltage (options)
Supply voltage (options)
Power
Degree of protection
Fine-wire fuse
Internal protection 125 mA for
Internal protection 250 mA for
Degree of protection, housing
Metering time adjustment (increments of 0.01 sec.)
Pre spraying time adjustment
(increments of 0.01 sec.)
After spraying time adjustment
(increments of 0.01 sec.)
Compressed air supply *
Spray air pressure range
Start signal floating contact or transistor (max.)
Reserve signal
(Capacitive key with make contact function)
Empty signal
(Capacitive key with make contact function)
Collective fault signal , Potential free (max.)
'Finished' signal , Potential free (max.)
Dimensions (W x H x D)
Housing material
Weight
* The compressed air must be clean, dry and free of oil. Divergence from the input
pressure in either direction (up or down) may result in impairment of function.
CAUTION!
Compressed air must be clean, dry and oil-free. Exceeding or underflow of
the supply pressure can impair the function.
0,01 to 99,99 sec.
0,00 to 99,99 sec.
0,00 to 99,99 sec.
0,45 (4,5) – 0,6 (6) MPa (bar)
0 - 0,38 (3,8) MPa (bar)
300 x 114 x 200 mm
Polystyrene,
acrylic paint finish
31
Technical data
Value Unit
50/ 60 Hz
230 /115 V AC
25 W
II
5 x 20 mm
230 V
115 V
32 IP
24 / 5 V / mA
pnp
pnp
24 / 2 V AC/DC/A
24 / 50 V AC/DC/mA
2,7 kg
417101439 Rev. 2-09.2019