Troubleshooting

9
Troubleshooting
Fault description
Unit not functioning
'Product: Reserve'
appears on display
'Product: Empty'
appears on display and red LED
flashes
'Alarm: Spray air'
appears on display and red LED
flashes
'Alarm: Control valve'
appears on display and red LED
flashes
When the cause of the problem has been removed, press 'ENTER' to
acknowledge the fault.
When the cause of the problem has been removed the applicator is ready
to work again.
417101439 Rev. 2-09.2019
Cause
Incorrect mains voltage
Defective fuse
'Reserve' signal active
Storage pack is emptyr
Disconnected or
defective cable
Connecting cable to
solenoid valve defective
Solenoid valve defective
Connecting cable to
solenoid valve defective
Solenoid valve defective
30
Remedy
Check metering unit settings (see
Ä Chapter 6.1.1.1 'Setting of
mains voltage' on page 21)
Replace fuse
Top up pack
(unit remains operable even
without topping up, see
8.1 'Changing the application tip'
on page 28)
Ä Chapter
Top up product (see
8.1 'Changing the application tip'
on page 28)
Reconnect 'Empty' signal cable or
replace it
Replace connecting cable
Replace solenoid valve
Replace connecting cable
Replace solenoid valve