Installation and start-up
6.1.2
Connection of the start signal cable
If a foot switch is used as the start signal transmitter unit, the cables will already be fitted
with the appropriate connectors.
The client will need to fit the appropriate connector if the unit is to be connected to a
control system.
Connector on cable:
Fig. 5: Connection of the start signal cable
1
Start signal
2
Alarm output
(max. 24 V AC/DC / 2 A)
3
EARTH (for start signal)
6.2
Setting of display contrast
The display contrast can be changed by inserting a screw-driver in a hole in the housing
base, and turning.
6.3
Compressed air connection
CAUTION!
The required valve control pressure must be at least 0,5 MPa (5 bar).
The compressed air must be free of moisture and oil, otherwise the
features of the glues would be significantly modified.
417101439 Rev. 2-09.2019
4
Common (common connection to alarm output and
'completed' message)
5
'Completed' message
(max. 24 V AC/DC / 50 mA)