Continuous Operation ( 'Cont' Led Illuminates ) - Ecolab MULTILINE 1000-S Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.2.1.1 Adjustment of metering time
Fig. 7: Adjustment of metering time
Pressing (for not less than 2 sec.) of the 'Up' (▲) or 'Down' (▼) buttons activates
metering time adjustment and the first place (digit) for metering time flashes on the
display. The required values can now be set using the 'Up' (▲) or 'Down' (▼) keys.
Press the 'ENTER' key to move on to the next place (next digit). After entering the final
digit, press the 'ENTER' key to confirm the value set and return the unit to 'Ready' state.
NOTICE!
Metering cannot be started by reception of an external signal while
metering time is being adjusted.
This adjustment does not affect the after run time for spray air.
7.2.2
Continuous operation ( 'CONT' LED illuminates
Metering starts when an external start pulse is received (that is the valve opens and
spray air is active).
Time is counted upward. If the start signal is discontinued, the valve will close and
spray air remains active up to the end of the after run time (see pre set after run
time).
The 'Finished' signal is transmitted to the exterior after expiry of the after run time.
27
)
417101439 Rev. 2-09.2019
Operation