Set Out Of Operation / Disassembly / Environmental Protection; Shutting Down; Dismantling - Ecolab MULTILINE 1000-S Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Set out of operation / disassembly / environmental
protection
12

Set out of operation / disassembly / environmental protection

Personnel:
DANGER!
Risk of injury due to the disregard of the specified personal protective
equipment (PPE)!
For all disassembly work, please respect the use of the PSA which is
specified on the product data sheet.
12.1

Shutting down

DANGER!
The procedures described here may only be carried out by skilled
personnel using PPE.
The procedure for shutting down is as follows:
1.
Before carrying out any subsequent work, isolate the electrical supply completely
first of all and secure it against being switched on again.
2.
Physically disconnect the entire power supply; dissipate stored residual energy.
3.
Drain and remove operating fluids and consumables.
4.
Remove the remaining processing materials and dispose of them
in an environmentally-friendly way.
12.2

Dismantling

DANGER!
Dismantling may only be carried out by skilled personnel using PPE.
Before commencing dismantling, ensure that the device has been fully
isolated from the power supply. Contact with live components can be fatal.
Activated electrical components can make uncontrolled movements and
lead to serious injury.
Carefully rinse all components which come into contact with the product in
order to remove chemical residue.
WARNING!
Danger of injury in case of improper dismantling!
Stored residual energy, components with sharp edges, points and corners,
on and in the system, or on the required tools can cause injuries.
417101439 Rev. 2-09.2019
n
Operator
n
Mechanic
n
Service personnel
n
Specialist
34

Publicité

Table des Matières
loading

Table des Matières